[A pig model of myocardial infarction by intracoronary embolization with gelatin sponge]

Zhonghua Yi Xue Za Zhi. 2005 Mar 9;85(9):599-601.
[Article in Chinese]

Abstract

Objective: We produced a large-animal model of myocardial infarction induced by transcatheter embolization of the left coronary artery using a gelatin sponge.

Methods: Seven pigs underwent transcatheter embolization of the left anterior descending artery (LAD) using gelatin sponge to produce anteroapical myocardial infarction (MI). 4 weeks later, Echocardiography, Coronary angiography and Pathology was performed, and the data were compared with those of the control group (n = 6).

Results: The procedure mortality was 1 of 7. In the MI group, the LV end-diastolic dimension increased (control versus MI: 37.0 mm +/- 3.4 mm and 50.8 mm +/- 6.1 mm, P < 0.01), the ejection fraction (EF) decreased (control versus MI: 62.3% +/- 2.9% and 36.6% +/- 2.1%, P < 0.001). Coronary angiography revealed the LAD remained occluded. The postmortem specimen showed a transmural MI scar in the anteroseptal and apical regions in the MI group and the LV volumes at 30 mm Hg were 81.4 ml +/- 4.3 ml, the scar areas were 18.4% +/- 1.6% of total left ventricular free wall and the scar thickness was 3.5 mm +/- 0.8 mm. Histologic samples in the MI group stained with Masson's trichrome showed massive fibrosis in the border zone and patchy fibrosis in the remote region in the LV free wall, whereas the control group showed no fibrosis.

Conclusion: This pig model of myocardial infarction is reliable, reproducible, and similar to the human condition, amenable to investigate other investigation.

Publication types

  • English Abstract

MeSH terms

  • Animals
  • Coronary Vessels
  • Disease Models, Animal*
  • Gelatin
  • Myocardial Infarction* / etiology
  • Porifera
  • Swine

Substances

  • Gelatin