Capsule 13C-urea breath test for the diagnosis of Helicobacter pylori infection

World J Gastroenterol. 2005 Mar 7;11(9):1361-4. doi: 10.3748/wjg.v11.i9.1361.

Abstract

Aim: To compare the accuracy of capsule 13C-urea breath test (UBT) with conventional invasive methods for the diagnosis of Helicobacter pylori infection.

Methods: One hundred patients received CLO test, histological examination, culture and 100- or 50-mg capsule UBT for the diagnosis of H pylori infection. H pylori infection was defined as those with positive culture or positive results from both histology and CLO test.

Results: Both the sensitivity and specificity of the 100-mg capsule UBT (n = 50) were 100%. The sensitivity and specificity of the 50-mg capsule UBT (n = 50) were 96.4 and 100%, respectively. Taken together, the accuracy of capsule UBT (n = 100) was higher than that of CLO test, histology and culture (100% vs 92%, 91% and 89%, respectively; P = 0.035, 0.018 and 0.005, respectively). Our data showed that the optimal timing of sampling for 100- and 50-mg capsule UBT was 15-30 and 6-15 min, respectively.

Conclusion: Capsule UBT has a higher accuracy compared with biopsy-based tests. It is an ideal method for the diagnosis of H pylori infection.

Publication types

  • Clinical Trial
  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy
  • Breath Tests / methods*
  • Capsules
  • Carbon Isotopes
  • Feces / microbiology
  • Female
  • Helicobacter Infections / diagnosis*
  • Helicobacter Infections / pathology
  • Helicobacter pylori*
  • Humans
  • Male
  • Middle Aged
  • Sensitivity and Specificity
  • Urea / metabolism*

Substances

  • Capsules
  • Carbon Isotopes
  • Urea