[F-18-fluordeoxyglucose positron emission tomography on patients with differentiated thyroid cancer who present elevated human serum thyroglobulin levels and negative I-131 whole body scan]

Rev Esp Med Nucl. 2005 Jan-Feb;24(1):5-13. doi: 10.1157/13070351.
[Article in Spanish]

Abstract

This study aimed to evaluate the role of Fluorine-18-fluorodeoxyglucose positron emission tomography (PET-FDG) in patients with elevated serum thyroglobulin (hTg) levels where thyroid cancer tissue does not concentrate radioiodine, rendering false-negative results on I-131 scanning.

Material and methods: Whole-body PET imaging using FDG was performed in 54 patients (37 female, 17 male) aged 17-88 years: 45 with papillary tumors and 9 with follicular tumors who were suspected of having recurrent thyroid carcinoma due to elevated thyroglobulin levels (hTg > 2 ng/ml) under thyroid-stimulating hormone (TSH > or = 30 microIU/ml) in whom the iodine scan was negative. All whole body scans were obtained with diagnostic doses (185 MBq). Whole body PET imaging was performed in fasting patients following i.v. administration of 370 MBq FDG while the patients were receiving full thyroid hormone replacement. Before PET, 99mTc methoxyisobutylisonitrile scintigraphy (99mTc-MIBI) was done in 14 patients and morphologic imaging in 26 by CT scan.

Results: Positive PET results confirmed the presence of hypermetabolic foci in 25/54 patients (46.29 %). Positive findings were found for PET-FDG in patients with hTg levels higher than 10 ng/ml receiving full thyroid hormone replacement. 99mTc-MIBI demonstrated lesions in 7/14 patients (50 %). PET-FDG and 99mTc-MIBI had congruent positive results in 4/7 patients. All the lesions found by CT were detected by PET-FDG, while recurrent disease was found in 12/21 patients with previous negative CT.

Conclusions: These results suggest that PET-FDG seems to be a promising tool in the follow-up of thyroid cancer and should be considered in patients suffering from differentiated thyroid cancer with suspected recurrence and/or metastases by elevated thyroglobulin levels, and negative I-131 whole body scans. PET-FDG might be more useful at hTg levels > 10 ng/ml.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • False Negative Reactions
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Iodine Radioisotopes
  • Male
  • Middle Aged
  • Neoplasm Metastasis
  • Neoplasm Recurrence, Local / diagnostic imaging
  • Positron-Emission Tomography*
  • Radiopharmaceuticals*
  • Retrospective Studies
  • Thyroglobulin / blood*
  • Thyroid Neoplasms / blood*
  • Thyroid Neoplasms / diagnostic imaging*

Substances

  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18
  • Thyroglobulin