Case report: Endovascular repair of a ruptured abdominal aortic aneurysm under local anaesthesia

Br J Radiol. 2005 Jan;78(925):62-4. doi: 10.1259/bjr/13370263.

Abstract

Abdominal aortic aneurysm (AAA) is a common degenerative condition affecting the elderly population. Rupture carries a high overall mortality. Elective endovascular stent graft repair is well described. We describe a patient with ruptured AAA and co-morbid conditions making him unfit for surgery and general or epidural anaesthesia, who was successfully treated by endovascular stent graft under local anaesthesia.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Anesthesia, Local
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortic Rupture / diagnostic imaging
  • Aortic Rupture / surgery*
  • Blood Vessel Prosthesis Implantation / methods
  • Endarterectomy / methods*
  • Humans
  • Male
  • Stents
  • Tomography, X-Ray Computed / methods