The aim of this work was to present the advantages of two polymeric cartridges (Oasis HLB from Waters and Abselut Nexus from Varian) for the solid-phase extraction of methadone enantiomers and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and of some benzodiazepines (diazepam, flunitrazepam, nitrazepam, oxazepam) in serum and urine in comparison with classical C18-bonded-silica cartridges or liquid extraction. After addition of serum or urine samples, these two cartridges were washed with a water-methanol mixture (95:5, v/v) and eluted with diethylether. After rapid evaporation, the residue was regenerated with mobile phase and injected either in a chiral column (Cyclobond I-2000 RSP) for methadone enantiomers and its metabolite or in a reversed-phase column (Symmetry Shield RP8) for benzodiazepines. The results showed that the chromatograms of blank serum and urine were cleaner than those obtained from classical solid-phase extraction or liquid extraction. The recoveries from these two polymeric cartridges were higher (95-102%) than those obtained by the two previous classical methods and the total time for extraction and solvent evaporation was also shorter (about 6-7 min). For methadone and benzodiazepine extraction, the use of acidic or alkaline buffer was not necessary.