Detection of antigen-antibody reaction using a fluorescent probe and its application to homogeneous competitive-type immunoassay for insulin

Biosci Biotechnol Biochem. 2004 Oct;68(10):2190-2. doi: 10.1271/bbb.68.2190.

Abstract

The interaction of bovine insulin with anti-human insulin antibody (mAb) was examined using a fluorescent probe. The fluorescence intensity of fluoresceinthiocarbamyl (FTC)-insulin was increased by adding mAb, and the increase was saturated at 53% at a molar ratio of FTC-insulin to mAb of 2.0. Based on the change in fluorescence intensity, a standard curve of the homogeneous competitive-type immunoassay was constructed, and the detection range of insulin was found to be 50-400 nM.

MeSH terms

  • Animals
  • Antigen-Antibody Reactions
  • Cattle
  • Humans
  • Immunoassay / methods
  • Insulin / analogs & derivatives*
  • Insulin / analysis*
  • Insulin Antibodies / immunology*
  • Spectrometry, Fluorescence / methods

Substances

  • Insulin
  • Insulin Antibodies
  • insulin, fluoresceinthiocarbamyl(B29)-