Urea biosensor based on PANi(urease)-Nafion/Au composite electrode

Biosens Bioelectron. 2004 Jul 30;20(1):15-23. doi: 10.1016/j.bios.2003.11.028.

Abstract

The polyaniline (PANi)-Nafion composite film was prepared onto the ceramic plate by the cyclic voltammetry (CV) method with the various cycle numbers. When the PANi-Nafion/Au/ceramic plate with the preparing cycle number of 5 was as working electrode, the cathodic peak current was achieved as 84.0 microA in 60 mg dl(-1) NH4Cl buffer solution. On the other hand, the small cathodic peak currents for buffer solution in the presence of 60 mg dl(-1) LiOH, NaCl and KCl, respectively, were found with the same composite electrode as working electrode. The cathodic peak current decreased from 84.0 to 16.3 microA in the 60 mg dl(-1) NH4Cl buffer solution when the cycle number for preparing PANi-Nafion/Au/ceramic plate composite electrode with the CV method increased from 5 to 15. The enzyme of urease was immobilized onto the PANi-Nafion/Au/ceramic plate composite film by the electrochemical immobilization and the casting methods and used as sensing electrode to detect the concentration of urea in the buffer solution. The sensitivity of composite electrode immobilized with the casting method was greater than that of electrochemical immobilization method. The sensitivity and the detecting limit of the urea sensor were found to be 0.7 and 5.27 microA (mg dl(-1))(-1)cm(-2), as well as 6 and 0.3 mg dl(-1), respectively, when urease was immobilized by glutaraldehyde (GA) cross-linker and Nafion network, respectively.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Biosensing Techniques / instrumentation
  • Biosensing Techniques / methods*
  • Blood Chemical Analysis / instrumentation
  • Blood Chemical Analysis / methods
  • Ceramics / chemistry
  • Coated Materials, Biocompatible / chemistry
  • Complex Mixtures / analysis
  • Complex Mixtures / chemistry
  • Electrochemistry / instrumentation
  • Electrochemistry / methods*
  • Electrodes*
  • Enzyme Stability
  • Enzymes, Immobilized / chemistry
  • Equipment Design
  • Equipment Failure Analysis
  • Fluorocarbon Polymers / chemistry*
  • Gold / chemistry*
  • Hydrogen-Ion Concentration
  • Manufactured Materials
  • Oxidation-Reduction
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Urea / analysis*
  • Urea / chemistry
  • Urease / chemistry*
  • Urinalysis / instrumentation
  • Urinalysis / methods

Substances

  • Coated Materials, Biocompatible
  • Complex Mixtures
  • Enzymes, Immobilized
  • Fluorocarbon Polymers
  • perfluorosulfonic acid
  • Gold
  • Urea
  • Urease