Reagents and methods for PET using bispecific antibody pretargeting and 68Ga-radiolabeled bivalent hapten-peptide-chelate conjugates

J Nucl Med. 2004 Jan;45(1):30-9.

Abstract

The aim of this work was to develop reagents and methods potentially useful in PET, using (68)Ga in a 2-step pretargeting protocol.

Methods: We prepared bispecific antibodies (bsAbs) for disease-specific targeting of carcinoembryonic antigen-positive cells and recognition of later-administered bivalent hapten-peptide conjugates. The secondary antibody arm (antibody 679) recognizes a histaminyl-succinyl-glycine (HSG) structural subunit. The bsAbs were prepared as Fab' x Fab' conjugates using chemical cross-linking methods and as bispecific diabodies using recombinant DNA technologies. A HSG-bivalent hapten conjugate bearing the macrocyclic ring chelating agent 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic acid (DOTA) was designed to be readily radiolabeled with (68)Ga taken directly from a (68)Ge/(68)Ga generator system. Reagents were tested in vitro and, then, for their targeting properties in a preclinical animal model of human cancer.

Results: A chemically cross-linked hMN-14 x 679 F(ab')(2) and a fully humanized bispecific diabody construct (BS1.5H), expressed in Escherichia coli, were prepared for this work. We synthesized the bivalent peptide termed IMP 241 [DOTA-Phe-Lys(HSG)-D-Tyr-Lys(HSG)-NH(2)] and labeled it with (68)Ga and (67)Ga at temperatures from 45 degrees C to 100 degrees C, over times of 15 min to 1 h, establishing 15 min at 95 degrees C as a useful condition for (68)Ga labeling. When we formulated the IMP 241 bivalent hapten-peptide with ammonium acetate buffer at pH 4-5 and eluted the (68)Ga from the generator directly into the peptide solution, we achieved an almost quantitative incorporation of the (68)Ga into IMP 241, as analyzed by size-exclusion high-performance liquid chromatography, after mixing the complex with the 679 antibody. For in vivo studies we used (67)Ga-IMP 241 as a surrogate for (68)Ga-IMP 241, in view of the short, 68-min half-life of the (68)Ga nuclide. The (67)Ga-IMP 241 was successfully pretargeted to human colon tumor xenografts in athymic mice with both the chemical and the diabody bispecific proteins. High tumor-to-normal tissue ratios for (67)Ga uptake were found for all tissues at 1 to 6 h after injection of (67)Ga-IMP 241. When using the BS1.5H diabody for pretargeting, tumor-to-blood, tumor-to-liver, and tumor-to-lung ratios of (67)Ga-IMP 241 at 1 and 3 h after injection were 41:1 and 137:1, 51:1 and 106:1, and 16:1 and 46:1, respectively.

Conclusion: The general approach described, along with the new compositions and the labeling methods we have developed, may eventually allow for use of (68)Ga-labeled specific targeting agents in a routine clinical PET application.

Publication types

  • Evaluation Study

MeSH terms

  • Animals
  • Antibodies, Bispecific* / chemistry
  • Cell Line, Tumor
  • Chelating Agents / chemistry
  • Colonic Neoplasms / diagnostic imaging*
  • Colonic Neoplasms / metabolism*
  • Haptens / chemistry
  • Humans
  • Indicators and Reagents / chemistry
  • Isotope Labeling / methods*
  • Metabolic Clearance Rate
  • Mice
  • Mice, Nude
  • Oligopeptides / chemistry
  • Oligopeptides / pharmacokinetics*
  • Organ Specificity
  • Organometallic Compounds / chemistry
  • Organometallic Compounds / pharmacokinetics*
  • Radiopharmaceuticals / pharmacokinetics
  • Tissue Distribution
  • Tomography, Emission-Computed / methods*

Substances

  • Antibodies, Bispecific
  • Chelating Agents
  • Haptens
  • Indicators and Reagents
  • Oligopeptides
  • Organometallic Compounds
  • Radiopharmaceuticals
  • gadolinium IMP241