Practical applications of the Fenton reaction to the removal of chlorinated aromatic pollutants. Oxidative degradation of 2,4-dichlorophenol

Environ Sci Pollut Res Int. 2003;10(6):379-84. doi: 10.1065/espr2003.06.155.

Abstract

Background: Chlorophenols (CPs) constitute a group of organic pollutants that are introduced into the environment as a result of several man-made activities, such as uncontrolled use of pesticides and herbicides, and as byproducts in the paper pulp bleaching. Promising removal technologies of chlorinated aromatics consist in the application of advanced oxidation processes (AOPs) that can provide an almost total degradation of a variety of contaminants. Among these, wide application find Fenton systems based on generation of reactive species having a high oxidizing power, such as hydroxyl radical HO*. Our objective was that of determining the overall degradation efficiency of the model compound 2,4-dichlorophenol (DCP) by thermal Fenton-type oxidation systems with a view toward defining in more details relevant process parameters, the effect of reaction temperature and of co-catalyst Cu2+.

Methods: Reaction conditions were similar to those generally adopted as optimal in many practical applications, i.e. pollutant/Fe2+ (as FeSO4) ratio ca. 20, Fe2+/Cu2+ (co-catalyst) 2:1, pH adjusted and controlled at pH 3, and H2O2 in excess (up to four-fold over the stoichiometric amount required for complete mineralization).

Results and discussion: The results demonstrate that it is advantageous to carry out the reaction at a temperature markedly higher (70 degrees C) than ambient. The stepwise addition of H2O2 in aliquots yields an efficient transformation, while allowing a convenient control of the reaction exothermicity. Under these conditions, the essentially complete removal of the initial DCP is accomplished using just one equiv of H2O2 during 15 min; excess H2O2 (5 equivalents) yields extensive substrate mineralization. Also relevant, at 70 degrees C dechlorination of the initial DCP (and of derived reaction intermediates) is remarkably extensive (3-5% residual TOX), already with the addition of 1 equiv of H2O2. At the end of the reaction, IC and IC-MS analyses of the solution reveal that only low-molecular weight carboxylic acid (acetic, formic, oxalic, malonic, tartaric, etc.) contribute to the residual TOC.

Conclusions: The whole of the results herein point to the advantage of performing the process at temperatures substantially higher than ambient (70 degrees C). Under the conditions adopted, almost complete degradation of the initial toxic compound can be achieved using hydrogen peroxide in fair excess (e.g., 3.5 equiv H2O2).

Recommendations and outlook: In applying practical Fenton-type degradation systems to heavily polluted wastes, either for the pre-treatment of waters with a high COD value prior to biodegradation or for complete mineralization of pollutants, the set up of appropriate reaction conditions appears to be a key factor. Also, it is desirable to keep the concentration of iron salts within the lower limits in order to minimize the production and disposal of iron oxide sludges.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chlorophenols / isolation & purification*
  • Environmental Pollution / prevention & control*
  • Hydrogen Peroxide / chemistry*
  • Hydroxyl Radical / chemistry
  • Iron / chemistry*
  • Oxidants / chemistry*
  • Oxidation-Reduction
  • Temperature

Substances

  • Chlorophenols
  • Fenton's reagent
  • Oxidants
  • Hydroxyl Radical
  • Hydrogen Peroxide
  • Iron