A quantitative method for optimized placement of continuous air monitors

Health Phys. 2003 Nov;85(5):599-609. doi: 10.1097/00004032-200311000-00008.

Abstract

Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.
  • Validation Study

MeSH terms

  • Aerosols
  • Air Pollutants, Radioactive / analysis*
  • Air Pollution, Indoor / analysis*
  • Nuclear Warfare
  • Occupational Exposure / analysis*
  • Occupational Health
  • Particle Size
  • Quality Control
  • Radiation Dosage
  • Radiation Protection / instrumentation
  • Radiation Protection / methods*
  • Radioactive Waste / analysis*
  • Radiometry / instrumentation
  • Radiometry / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Aerosols
  • Air Pollutants, Radioactive
  • Radioactive Waste