The clinical utility of string-PCR test in diagnosing Helicobacter pylori infection

Hepatogastroenterology. 2003 Sep-Oct;50(53):1208-13.

Abstract

Background/aims: Non-invasive string test has been reported as being convenient and capable of yielding bacteria by means of gastric juice sampling in the diagnosis of Helicobacter pylori infection. Molecular methods, such as polymerase chain reaction for the amplification of DNA, are desirable for the detection of minute quantities of H. pylori. We planned to evaluate the diagnostic efficiency of the combination of the string test and polymerase chain reaction and determine whether the string polymerase chain reaction test could obtain more information in conditions where the bacterial load is so low that other diagnostic tests fail to confirm the presence of H. pylori.

Methodology: We enrolled 48 dyspeptic patients, including 29 males and 19 females, with a mean age of 52.5 years. Each patient received endoscopy and biopsy-based tests, including RUT (rapid urease test), cultures, and histology, followed by 13C-UBT (13Carbon urea breath test). We used the string test, (Entero-Test H. pylori, HDC Corporation, CA, US), for gastric juice sampling. The specimen was further analyzed by polymerase chain reaction for the presence of H. pylori with the primer for cagA gene, which is highly prevalent in Taiwan. H. pylori infection was considered as positive when either culture yield was positive, or when two of the other three tests, including RUT, histology, and 13C-UBT, were positive.

Results: Of the total 48 patients, 34 patients were H. pylori-positive, and 14 were H. pylori-negative. A fragment of 349 bp of polymerase chain reaction products was detected by agarose gel electrophoresis in 32 out of 34 patients who was classified as H. pylori-positive. The sensitivity, specificity, positive predictive value, and negative predictive value of the string polymerase chain reaction test were 94.12%, 96.97%, 92.86%, and 86.67%, respectively. These results are comparable to 13C-UBT and RUT, and better than histology and culture. One subject, who tested as H. pylori-negative according to the diagnostic criteria, had positive 13C-UBT and string polymerase chain reaction test results. Further sequencing of the DNA obtained from the results of polymerase chain reaction product was performed and it showed 98% identities with the known sequence of cagA strain H. pylori (GenBank accession number: AF249275).

Conclusions: The string polymerase chain reaction test is non-invasive and provides direct bacterial yields. Its diagnostic efficiency is comparable with 13C-UBT and RUT in detecting H. pylori infection. Also, with the assistance of polymerase chain reaction and DNA sequencing, we can diagnose H. pylori infection even when the bacterial load is low. Further application of string polymerase chain reaction test in the genetic analysis of virulent and resistant strains seems promising.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antigens, Bacterial
  • Bacterial Proteins
  • Breath Tests
  • Electrophoresis, Agar Gel
  • Female
  • Gastric Juice / microbiology*
  • Helicobacter Infections / diagnosis*
  • Helicobacter pylori*
  • Humans
  • Male
  • Middle Aged
  • Polymerase Chain Reaction / methods*
  • Sequence Analysis, DNA

Substances

  • Antigens, Bacterial
  • Bacterial Proteins
  • cagA protein, Helicobacter pylori