Determination of urinary hippuric acid by micellar electrokinetic capillary chromatography

J Chromatogr B Analyt Technol Biomed Life Sci. 2003 Aug 15;793(2):223-8. doi: 10.1016/s1570-0232(03)00265-4.

Abstract

We propose a method for the simultaneous determination of hippuric acid (HA) and creatinine based on capillary micellar electrokinetic chromatography. Experimental conditions were 20 mM sodium phosphate, pH 7.20, 25 mM sodium dodecyl sulfate, 5% (v/v) acetonitrile. Electropherograms evidenced HA and creatinine peaks in less than 12 min. The method showed good linearity for both analytes and satisfactory within-day precision. The present method, which is accurate, sensitive, rapid and simple, may be applied to single-spot urine samples.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, Micellar Electrokinetic Capillary / methods*
  • Creatinine / urine
  • Glomerular Filtration Rate
  • Hippurates / urine*
  • Magnetic Resonance Spectroscopy
  • Reproducibility of Results

Substances

  • Hippurates
  • Creatinine
  • hippuric acid