Magnetic resonance urography by virtual reality modelling

APMIS Suppl. 2003:(109):26-8.

Abstract

Purpose: The purpose of this study was to create a 3D visualization of the urinary tract by a novel virtual reality approach, and to evaluate the usefulness of this method for papillary classification as compared with 2D urogram obtained by maximum intensity projection (MIP).

Materials and methods: In one healthy pig, magnetic resonance urography was performed using a T1-weighted 3D gradient echo pulse sequence. Post-processing was performed by means of an MIP algorithm and by using 3D virtual reality modelling, followed by manual classification of papillae as being either simple or compound.

Results: The 2D MIP urogram demonstrated 6 simple and 6 compound papillae, whereas the 3D urogram demonstrated 5 simple and 7 compound papillae. In both urograms, some papillae were unsuccessfully classified.

Conclusion: The possibility of using virtual reality devices allowed 3D rotation and offered additional diagnostic information. However, further studies should reveal its feasibility in diseased kidneys.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Magnetic Resonance Imaging*
  • Models, Anatomic*
  • Swine
  • Urinary Tract / anatomy & histology*