Application of cast iron-platinum keeper to a collapsible denture for a patient with constricted oral opening: a clinical report

J Prosthet Dent. 2003 Jul;90(1):6-9. doi: 10.1016/s0022-3913(03)00266-x.

Abstract

Insertion of a denture is especially difficult for patents with a constricted oral opening. This report describes the fabrication of a collapsible removable partial denture with a cast iron-platinum attachment for a partially edentulous woman with a constricted oral opening resulting from rheumatoid arthritis and a craniotomy for a subarachnoid hemorrhage.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Arthritis, Rheumatoid / complications
  • Chromium Alloys
  • Dental Alloys*
  • Denture Bases
  • Denture Design*
  • Denture, Partial, Removable*
  • Female
  • Humans
  • Iron*
  • Magnetics / instrumentation
  • Platinum*
  • Temporal Muscle / surgery
  • Temporomandibular Joint Disorders / complications

Substances

  • Chromium Alloys
  • Dental Alloys
  • Platinum
  • Iron