Accuracy of endometrial biopsy with the Cornier pipelle for diagnosis of endometrial cancer and atypical hyperplasia

Eur J Gynaecol Oncol. 2003;24(3-4):279-81.

Abstract

Objective: To establish the accuracy of endometrial biopsy with the Cornier pipelle in the diagnosis of endometrial cancer and atypical endometrial hyperplasia in our milieu.

Material and method: We reviewed 1,535 anatomopathologic reports on endometrial biopsies taken from outpatients using the Cornier pipelle between 1997 and 2000, in pre- and postmenopausal patients with abnormal vaginal bleeding. In 168 patients (10.9%), curettage and/or hysterectomy was subsequently carried out. In these cases, the anatomopathologic reports were compared to determine sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and likelihood ratio (LR).

Results: Sensitivity was 84.2%, specificity was 99.1%, accuracy was 96.9%, PPV was 94.1%, NPV was 93.7% and LR was 93.5. In 249 cases (16.09%) the material was insufficient for study.

Conclusion: We determined that endometrial biopsy taken with the Cornier pipelle is, as we practice it, an accurate method for diagnosis of endometrial cancer and its precursor, atypical hyperplasia.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle / instrumentation*
  • Carcinoma / pathology*
  • Cohort Studies
  • Diagnosis, Differential
  • Dilatation and Curettage / instrumentation
  • Dilatation and Curettage / methods
  • Endometrial Hyperplasia / pathology*
  • Endometrial Neoplasms / pathology*
  • Endometrial Neoplasms / surgery
  • Female
  • Humans
  • Hysterectomy
  • Middle Aged
  • Predictive Value of Tests
  • Retrospective Studies
  • Sensitivity and Specificity