A simple measure of flow disorder and wall shear stress in phase contrast MRI

Magn Reson Med. 2003 Mar;49(3):543-50. doi: 10.1002/mrm.10409.

Abstract

A method for estimating the standard deviation of velocity within a voxel is proposed. This estimate is based on data collected using a phase-contrast MRI technique. Simulations are presented to characterize the estimate and in vivo data are shown. Several different uses of the estimate are proposed, including obtaining a measure of wall shear stress, aiding in data combination from different phase-contrast MRI datasets, and mitigation of flow void artifacts.

Publication types

  • Review

MeSH terms

  • Artifacts
  • Blood Flow Velocity / physiology
  • Blood Vessels / physiopathology*
  • Computer Simulation
  • Contrast Media
  • Humans
  • Magnetic Resonance Angiography / methods*
  • Signal Processing, Computer-Assisted*

Substances

  • Contrast Media