Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation

AJR Am J Roentgenol. 2003 Feb;180(2):357-62. doi: 10.2214/ajr.180.2.1800357.

Abstract

Objective: To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging.

Subjects and methods: The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison.

Results: High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect.

Conclusion: High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adult
  • Cartilage, Articular / anatomy & histology*
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Processing, Computer-Assisted
  • Imaging, Three-Dimensional
  • Knee Joint / anatomy & histology*
  • Magnetic Resonance Imaging / methods*
  • Male