Endovascular gamma-irradiation to prevent recurrent femoral in-stent restenosis. A case report

Cardiovasc Radiat Med. 2002 Jan-Mar;3(1):7-11. doi: 10.1016/s1522-1865(02)00132-4.

Abstract

We report about a patient with twice recurrence of femoral in-stent restenoses. Centered endoluminal gamma-irradiation with 192 iridium was performed immediately after the second stent recanalization. The irradiation dose was 14 Gy calculated at 2-mm depth of vessel wall. One-year follow-up demonstrates neither clinical nor angiographic evidence of restenosis.

Publication types

  • Case Reports

MeSH terms

  • Arterial Occlusive Diseases / complications
  • Arterial Occlusive Diseases / radiotherapy
  • Arterial Occlusive Diseases / surgery
  • Blood Vessel Prosthesis Implantation
  • Female
  • Femoral Artery / pathology
  • Femoral Artery / surgery
  • Gamma Rays / therapeutic use*
  • Graft Occlusion, Vascular / etiology
  • Graft Occlusion, Vascular / prevention & control*
  • Humans
  • Intermittent Claudication / complications
  • Intermittent Claudication / radiotherapy
  • Intermittent Claudication / surgery
  • Middle Aged
  • Recurrence
  • Stents*