Abstract

Objective: To improve the exercise ECG analysis for non-invasively detection of myocardial ischemia.

Method: The newly developed measuring system of exercise ECG defines ST segment area and STA/HR slope as the new characteristic parameters, thus can sensitively detect myocardial ischemia. Some methods were proposed to reduce noise and artifacts for effective sampling of exercise ECG.

Result: 14 exercise ECG records were sampled and analyzed in clinical exercise test. It was found that the new parameters are very effective and sensitive to myocardial ischemia. The results show that the method is reliable and stable.

Conclusion: The method improves one of the evaluating indexes of exercise ECG analysis. It is quite promising for clinical application in future.

Publication types

  • English Abstract

MeSH terms

  • Aerospace Medicine
  • Electrocardiography / methods*
  • Exercise Test
  • Humans
  • Myocardial Ischemia / diagnosis*