[Pulse oximetry screening for sleep-disordered breathing in stroke]

Pneumologie. 2002 Jun;56(6):357-62. doi: 10.1055/s-2002-32170.
[Article in German]

Abstract

Background: The prevalence of sleep-disordered breathing, particularly obstructive sleep apnea, among stroke patients is high. Routine screening with the current diagnostic gold standard of polysomnography is not feasible. Pulse oximetry could be a simple screening test.

Methods: The signal of pulse oximetry, recorded during full polysomnography in 184 stroke patients during neurological rehabilitation, was analyzed automatically by software for desaturations >/= 4 %. The polysomnographic apnoea-hypopnoea-index (AHI) was used as the diagnostic gold standard and compared with the oxygen desaturation index (ODI).

Results: Correlation between AHI of PSG and ODI of oximetry was r = 0.84 (p < 0.001). Dependent on the definition of SDB (AHI 10, 15, 20 or 30/h) and the cut-off-point for the ODI (e. g. 15/h) sensitivity was 32 - 83 % and specificity 99 - 96 %. The diagnostic accuracy as determined by the area under the ROC-curve was 96 %.

Conclusion: Automated analysis of pulse oximetry gives reasonable results for screening for SDB in stroke patients and could be used in populations with high pre-test probability.

Publication types

  • English Abstract

MeSH terms

  • Female
  • Humans
  • Male
  • Middle Aged
  • Oximetry / methods*
  • Oxygen / blood*
  • Polysomnography
  • ROC Curve
  • Regression Analysis
  • Respiration Disorders / blood
  • Respiration Disorders / diagnosis*
  • Sleep Wake Disorders / blood
  • Sleep Wake Disorders / diagnosis*
  • Stroke / blood
  • Stroke / complications*
  • Stroke / physiopathology*

Substances

  • Oxygen