Comparison of methods for fluorescent detection of viable, dead, and total Escherichia coli O157:H7 cells in suspensions and on apples using confocal scanning laser microscopy following treatment with sanitizers

Int J Food Microbiol. 2002 Mar 25;74(1-2):37-45. doi: 10.1016/s0168-1605(01)00714-0.

Abstract

The influence of treating Escherichia coli O157:H7 cells labeled with an enhanced green fluorescent protein (EGFP) plasmid with 20 microg/ml active chlorine, 100 mg/ml hydrogen peroxide, and 80 mg/ml acetic acid on fluorescence intensity was determined. In addition, fluorescent staining methods to differentiate viable and dead E. coli O157:H7 cells on the cuticle of Red Delicious cv. apples following treatment with water or 200 microg/ml active chlorine were evaluated. Suspensions of E. coli O157:H7 EGFP+ cells were exposed to chemical treatment solutions for 0, 30, 60, 120, or 300 s before populations (log10 cfu/ml) were determined by surface plating, and fluorescence intensities of suspensions and individual cells were measured using spectrofluorometry and confocal scanning laser microscopy (CSLM), respectively. The relative fluorescence intensity of suspensions and individual cells changed upon exposure to various treatments. Results indicate that the use of EGFP to tag E. coli O157:H7 may not be appropriate for investigations seeking to microscopically differentiate viable and dead cells on produce following surface treatment with sanitizers. SYTOX Orange and SYTOX Green nucleic acid stains fluorescently labeled dead E. coli O157:H7 cells attached to apple cuticles more intensely than did propidium iodide. A cross-signal occurred between CSLM photomultipliers when examining tissues treated with SYTOX Orange to detect dead cells and antibody labeled with Alexa Fluor 488 to detect total (dead and viable) cells. Because of the possibility of cross-signal resulting in an overestimation of the number of dead cells on apples and, perhaps, other produce treated with these stains, SYTOX Green is preferred to detect dead cells and antibody labeled with Alexa Fluor 594 is preferred to detect the total number of cells on apple surfaces following treatment with sanitizers. The performance of SYTOX Green in combination with Alexa Fluor 594 to detect dead and total cells of E. coli O157:H7 on other produce remains to be determined.

Publication types

  • Comparative Study

MeSH terms

  • Acetic Acid / pharmacology
  • Anti-Infective Agents, Local / pharmacology*
  • Chlorine / pharmacology
  • Colony Count, Microbial
  • Escherichia coli O157 / drug effects
  • Escherichia coli O157 / growth & development
  • Escherichia coli O157 / isolation & purification*
  • Fluorescent Dyes*
  • Hydrogen Peroxide / pharmacology
  • Indicators and Reagents
  • Malus / microbiology*
  • Malus / ultrastructure
  • Microscopy, Confocal
  • Organic Chemicals

Substances

  • Anti-Infective Agents, Local
  • Fluorescent Dyes
  • Indicators and Reagents
  • Organic Chemicals
  • SYTOX Green
  • SYTOX Orange dye
  • Chlorine
  • Hydrogen Peroxide
  • Acetic Acid