The intraocular pressure of 12 apparently healthy juvenile loggerhead sea turtles (Caretta caretta) was determined by applanation tonometry while the turtles were held in dorsoventral, ventrodorsal, and head-down suspended positions. The median intraocular pressures were 5 mmHg (range 4 to 9 mmHg) in the dorsoventral position, 7 mmHg (range 5 to 12 mmHg) in the ventrodorsal position, and 23 mmHg (range 17 to 33 mmHg) in the suspended position.