Coronary magnetic resonance angiography: experimental evaluation of the new rapid clearance blood pool contrast medium P792

Magn Reson Med. 2001 Nov;46(5):932-8. doi: 10.1002/mrm.1279.

Abstract

The signal-enhancing characteristics of a new monodisperse monogadolinated macromolecular MR contrast medium (P792) were evaluated for magnetic resonance angiography (MRA) of the coronary arteries. A total of 15 cardiac examinations were performed in pigs at 1.5 T using a 3D gradient-echo sequence. Images were acquired during breath-hold before and up to 35 min after IV injection of Gd-DTPA (0.3 mmol Gd/kg), Gd-BOPTA (0.2 mmol Gd/kg), and P792 (13 micromol Gd/kg). An increase in the signal-to-noise ratio (SNR) of 97% +/- 17%, 108% +/- 37%, and 109% +/- 31% in coronary arteries and of 82% +/- 19%, 82% +/- 24%, and 28% +/- 18% in myocardium, respectively, was measured during the first postcontrast acquisition. The blood-to-myocardium signal-difference-to-noise ratio (SDNR) was significantly higher for P792 than for the other Gd compounds (P <.05) for up to 15 min after injection. Qualitative assessment showed that visualization of the coronary arteries and their branches was significantly better for P792 compared to the low-molecular Gd compounds (P <.05). The blood pool contrast medium P792 is well suited for MRA of the coronary arteries.

Publication types

  • Comparative Study

MeSH terms

  • Animals
  • Contrast Media
  • Coronary Vessels / anatomy & histology*
  • Gadolinium
  • Gadolinium DTPA
  • Heterocyclic Compounds*
  • Imaging, Three-Dimensional
  • Magnetic Resonance Angiography / methods*
  • Meglumine / analogs & derivatives*
  • Organometallic Compounds*
  • Swine
  • Swine, Miniature

Substances

  • Contrast Media
  • Heterocyclic Compounds
  • Organometallic Compounds
  • gadobenic acid
  • Meglumine
  • Gadolinium
  • Gadolinium DTPA
  • contrast agent P792