[Reporting echocardiography exams with the G8-Cardio ANMCO software]

Ital Heart J Suppl. 2001 Mar;2(3):258-67.
[Article in Italian]

Abstract

Background: The availability of a common computerized program for echocardiographic study archiving and reporting at national and/or international level could make it possible to standardize the echo reports of different echocardiographic laboratories, and to use the wealth of data thus obtainable with echocardiography, and to exploit its capillary territorial distribution, with the aim of collecting echocardiographic data in a standard format for epidemiological, scientific and administrative purposes.

Methods: To develop such a software, an ad hoc joint National Association of Hospital Cardiologists and Italian Society of Echocardiography task force worked in conjunction with the Italian Branch of Agilent Technologies to standardize the phraseology of accepted echocardiographic terms and of the quantitative parameters derived from transthoracic and transesophageal echocardiographic examination at rest as well as during exercise and pharmacological stress, and to develop an ad hoc software. This echocardiographic study archiving and reporting program is part of the whole G8-Cardio ANMCO software developed to computerize the whole cardiological chart. The software has been developed by Agilent Technologies to provide a fast, easy-access and easy to use report generator for the non-computer specialist using DBMS Oracle 7.3 database and Power Builder 5.0 to develop a user-friendly interface.

Results: The number of qualitative and quantitative variables contained in the program is 733 for echocardiography at rest, while it depends on the stressor and on the length of the examination for the stress echo (dipyridamole 214-384, dobutamine 236-406, exercise 198-392). The program was tested and refined in our laboratory between November 1999 and May 2000. During this time period, 291 resting and 56 stress echocardiographic studies were reported and recorded in a database. On average, each resting echocardiographic study lasting 10 +/- 4 (range 5-17) min was recorded using 50 +/- 11 (range 33-67) variables and 41,566 bytes of hard-disk memory space. Stress echocardiographic studies, each lasting 7 +/- 5 (range 5-21) min, were recorded using 143 +/- 74 (range 38-194) variables and 38,531 bytes of hard-disk memory space.

Conclusions: To our knowledge this software represents the first experience of a common computerized program for echo archiving and reporting carried out at national level.

Publication types

  • English Abstract

MeSH terms

  • Diagnosis, Computer-Assisted*
  • Echocardiography / methods*
  • Humans
  • Software*