Evaluation of a novel vitamin E coated cellulosic membrane hollow fiber dialyzer

ASAIO J. 2001 Jan-Feb;47(1):66-73. doi: 10.1097/00002480-200101000-00015.

Abstract

Adverse physiologic effects accompany hemodialysis. Biocompatible dialyzer membranes may both limit oxidative stress and decrease beta2-microglobulin production, thereby reducing patient morbidity. We compared standard solute clearance, lipid, and antioxidant effects of a novel cellulosic membrane dialyzer modified with covalently bonded vitamin E (Excebrane Clirans E15, Terumo Australia) with standard cellulosic and polysulphone membrane dialyzers. Stable adult hemodialysis patients taking no lipid lowering or antioxidant therapy (n = 17; 9 male, 8 female) were recruited into a 10 week, prospective, unblinded study. Measurements were made at baseline on their usual dialyzer and after 2, 4, and 10 weeks of Excebrane use. Excebrane demonstrated good in vivo clearance of standard solutes relative to surface area. Predialysis beta2-microglobulin levels were unchanged with time and were significantly lower postdialysis than with cellulose acetate (p < 0.05). Oxidized low density lipoprotein levels as measured by nitrotyrosine residues were high predialysis, but tended to decrease with both membranes (p > 0.05). Total antioxidant status fell during dialysis (p < 0.0005), but plasma vitamin A and E concentrations increased (p = 0.007 and p = 0.02, respectively). Baseline vitamin A levels were high in all patients and, along with vitamin E, total antioxidant status and lipid profiles did not change over time with Excebrane use. Excebrane is an efficient, biocompatible membrane with no deleterious effects on beta2-microglobulin or lipids. More long-term study is merited.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Cellulose / analogs & derivatives
  • Creatinine / blood
  • Female
  • Humans
  • Kidney Failure, Chronic / therapy*
  • Lipids / blood
  • Lipoproteins, LDL / blood
  • Male
  • Membranes, Artificial*
  • Middle Aged
  • Oxidative Stress
  • Phosphates / blood
  • Renal Dialysis / instrumentation*
  • Urea / blood
  • Vitamin A / blood
  • Vitamin E / blood
  • Vitamin E / therapeutic use*
  • Water
  • beta 2-Microglobulin / blood

Substances

  • Lipids
  • Lipoproteins, LDL
  • Membranes, Artificial
  • Phosphates
  • beta 2-Microglobulin
  • oxidized low density lipoprotein
  • Water
  • Vitamin A
  • Vitamin E
  • acetylcellulose
  • Urea
  • Cellulose
  • Creatinine