Adiabatic calorimetric decomposition studies of 50 wt.% hydroxylamine/water

J Hazard Mater. 2001 Mar 19;82(1):13-24. doi: 10.1016/s0304-3894(00)00356-3.

Abstract

Calorimetric data can provide a basis for determining potential hazards in reactions, storage, and transportation of process chemicals. This work provides calorimetric data for the thermal decomposition behavior in air of 50wt.% hydroxylamine/water (HA), both with and without added stabilizers, which was measured in closed cells with an automatic pressure tracking adiabatic calorimeter (APTAC). Among the data provided are onset temperatures, reaction order, activation energies, pressures of noncondensable products, thermal stability at 100 degrees C, and the effect of HA storage time. Discussed also are the catalytic effects of carbon steel, stainless steel, stainless steel with silica coating, inconel, titanium, and titanium with silica coating on the reaction self-heat rates and onset temperatures. In borosilicate glass cells, HA was relatively stable at temperatures up to 133 degrees C, where the HA decomposition self-heat rate reached 0.05 degrees C/min. The added stabilizers appeared to reduce HA decomposition rates in glass cells and at ambient temperatures. The tested metals and metal surfaces coated with silica acted as catalysts to lower the onset temperatures and increase the self-heat rates.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Calorimetry
  • Chemical Industry
  • Hazardous Substances*
  • Hydroxylamine / chemistry*
  • Temperature
  • Water

Substances

  • Hazardous Substances
  • Water
  • Hydroxylamine