Pharmacological mydriasis and optic disc examination

Br J Ophthalmol. 2000 Aug;84(8):894-8. doi: 10.1136/bjo.84.8.894.

Abstract

Aim: To determine whether pharmacological mydriasis leads to a significant difference in interobserver agreement of optic disc measurement compared with examination without mydriasis.

Method: A cross sectional study was performed with a pair of observers examining the optic disc of two randomised groups of patients, one group before diagnostic mydriasis, and the other afterwards. Horizontal and vertical disc diameters and cup/disc ratios were measured with a 78 dioptre lens. The study was repeated with another observer pair and two further groups of patients.

Results: In study A 86 subjects were examined in total (52 without and 34 with mydriasis). In study B 87 subjects were examined (45 without and 42 with mydriasis). The 95% limits of agreement of the cup/disc ratio measurement differences were significantly larger without mydriasis (p<0.001 for all studies (F test)). For both studies examination after mydriasis gave significantly greater agreement for vertical and horizontal cup/disc ratios. The cases with good agreement (0.1 difference or better) for vertical cup/disc ratios were 37/52 (72%) and 34 /45 (76%) without mydriasis and 33/34 (97%) and 40/42 (95%) respectively with mydriasis. Similar differences were recorded for horizontal cup/disc ratios. Disc diameter measurement results showed similar differences in study A but were not affected by mydriasis in study B.

Conclusions: Examination of the optic disc without pharmacological mydriasis gives significantly poorer interobserver agreement. In this study, the mean 95% limits of agreement values for all cup/disc ratio values were 0.27 for examination without mydriasis and 0.13 for examination with mydriasis. A measure outside these limits would suggest a real difference. This study indicates that mydriasis is important for reproducible clinical examination in glaucoma.

Publication types

  • Clinical Trial
  • Randomized Controlled Trial

MeSH terms

  • Cross-Sectional Studies
  • Glaucoma / diagnosis*
  • Humans
  • Mydriatics / pharmacology*
  • Observer Variation*
  • Optic Disk* / anatomy & histology*
  • Prospective Studies
  • Pupil / drug effects
  • Pupil / physiology

Substances

  • Mydriatics