Abstract

Study design: The internal architecture of cervical spine pedicles was investigated by thin sectioning and digitization of radiographic images.

Objectives: To provide quantitative information on the internal dimensions and cortical shell thicknesses of the middle and lower cervical pedicles.

Summary of background data: Although there have been a number of studies presenting data on the external dimensions of the cervical pedicle, little is known regarding its internal architecture and cortical shell thickness along the pedicle axis.

Methods: Twenty-five human cervical vertebrae (C3-C7) were secured to a thin-sectioning machine to produce three 0.7-mm-thick pedicle slices along its axis. Plain radiographs of the pedicle slices were scanned and digitized to facilitate measurement of the internal dimensions. Computer software was specifically developed to determine the external dimensions (i.e., pedicle height and width) and the internal dimensions (i.e., cortical shell thicknesses of the superior, inferior, lateral, and medial walls and the cancellous core height and width) of cervical pedicles.

Results: Superior and inferior wall cortical thicknesses of pedicle thin slices were similar, whereas the lateral wall cortical thickness was significantly smaller than the medial wall thickness. The medial cortical shell (average value range: 1.2-2.0 mm) was measured to be 1.4 to 3.6 times as thick as the lateral cortical shell (average value range: 0.4-1.1 mm). When medial and lateral cortical thicknesses were normalized for external dimensions, the combined cortical shell thickness was thinnest at C7 (average value range: 18. 6-25.6% of the external width), and this result was statistically significant when compared with other vertebral levels.

Conclusions: The cervical pedicle is a complex, three-dimensional structure exhibiting extensive variability in internal morphology. Characteristics of the cervical pedicle at different spinal levels must be noted before transpedicular screw fixation.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Bone Screws
  • Cervical Vertebrae / anatomy & histology*
  • Cervical Vertebrae / diagnostic imaging
  • Cervical Vertebrae / surgery
  • Humans
  • Joint Instability / surgery
  • Microtomy
  • Radiography
  • Reference Standards
  • Spinal Fusion