Hazardous peak concentrations of hydrogen sulfide gas related to the sewage purification process

AIHAJ. 2000 Jan-Feb;61(1):107-10.

Abstract

The concentration of hydrogen sulfide in the atmosphere of a sewage purification plant in Norway was studied. Continuous measurements over several 3-week periods showed that the concentrations generally were lower than 2 ppm, but peak concentrations over 100 ppm were discovered. Rapid onset and decline characterized these peak concentrations, which occurred at regular intervals. Through evaluation of the time pattern of these peaks compared with plant operations, a specific process was identified as the likely causative factor of the spikes. Through simple remedial actions the hydrogen sulfide concentration associated with this activity was reduced from above 100 ppm to less than 2 ppm. Olfactory fatigue to hydrogen sulfide and strong offensive odors from other compounds in the sewage makes smell ineffective for signaling high concentrations. Peak concentrations may therefore pass unnoticed unless detected with continuous measuring equipment. The risk for exposure may be reduced by enclosing processes and through the use of spot extraction ventilation in areas with compacted anaerobic waste material.

MeSH terms

  • Air Pollutants, Occupational / analysis*
  • Humans
  • Hydrogen Sulfide / analysis*
  • Occupational Exposure / prevention & control*
  • Safety Management* / methods
  • Sewage*
  • Waste Management / standards*

Substances

  • Air Pollutants, Occupational
  • Sewage
  • Hydrogen Sulfide