[The use of automated speech recognition in diagnostic radiology]

Rofo. 1999 Nov;171(5):400-4. doi: 10.1055/s-1999-262.
[Article in German]

Abstract

Purpose: Applicability and benefits of digital speech recognition in diagnostic radiology were tested using the speech recognition system SP 6000.

Methods: The speech recognition system SP 6000 was integrated into the network of the institute and connected to the existing Radiological Information System (RIS). Three subjects used this system for writing 2305 findings from dictation. After the recognition process the date, length of dictation, time required for checking/correction, kind of examination and error rate were recorded for every dictation. With the same subjects, a correlation was performed with 625 conventionally written finding.

Results: After an 1-hour initial training the average error rates were 8.4 to 13.3%. The first adaptation of the speech recognition system (after nine days) decreased the average error rates to 2.4 to 10.7% due to the ability of the program to learn. The 2nd and 3rd adaptations resulted only in small changes of the error rate. An individual comparison of the error rate developments in the same kind of investigation showed the relative independence of the error rate on the individual user.

Conclusion: The results show that the speech recognition system SP 6000 can be evaluated as an advantageous alternative for quickly recording radiological findings. A comparison between manually writing and dictating the findings verifies the individual differences of the writing speeds and shows the advantage of the application of voice recognition when faced with normal keyboard performance.

Publication types

  • English Abstract

MeSH terms

  • Germany
  • Humans
  • Medical Records Systems, Computerized*
  • Radiography*
  • Voice*