The fate of stable cemented acetabular components retained during revision of a femoral component of a total hip arthroplasty

J Bone Joint Surg Am. 1999 Dec;81(12):1682-91. doi: 10.2106/00004623-199912000-00005.

Abstract

Background: The decision as to whether to revise or retain a well fixed cemented acetabular component during revision of a femoral component is especially difficult; the rate of loosening of cemented acetabular components is high, whereas that of porous-coated acetabular components inserted during revision is low. However, removal of a well fixed cemented acetabular component can result in increased operative morbidity and cost and in loss of acetabular bone. Data that can be used to predict the long-term survival of retained well fixed cemented acetabular components are therefore needed.

Methods: We studied the five to thirteen-year clinical and radiographic results in a group of twenty-six consecutive patients in whom a well fixed cemented acetabular component had been retained during revision of a femoral component. Typical demographic data on the patients and information about the components were recorded, and the cemented acetabular components were graded as A through F, according to the system of Ranawat et al., at the time of the femoral revision. The average duration of follow-up was 8.4 years (range, 5.0 to 12.7 years). No patient was lost to follow-up.

Results: Four acetabular components (15 percent) had progressive radiolucency (at forty-eight, forty-eight, fifty-nine, and seventy-five months after the femoral revision) and were considered radiographically loose despite not being associated with symptoms. All four components were graded as either E or F at the time that they were retained during the femoral revision; radiographic loosening was significantly related to these two grades (p < 0.01). No acetabular component with a grade of A, B, C, or D loosened. The components that loosened had been in vivo for a relatively shorter, as opposed to longer, duration before the femoral revision compared with the components that did not loosen (p < 0.05).

Conclusions: Retention of the well fixed cemented acetabular components was associated with good clinical results but with a 15 percent rate of loosening. Revision of a cemented acetabular component solely on the basis of the duration that it was in vivo or whether a previous revision had been done does not appear to be warranted. Our findings suggest that acetabular components with a grade of A, B, C, or D at the time of a femoral revision may be retained, as these components continued to function at the time of the five to thirteen-year follow-up in the current study.

Publication types

  • Comparative Study

MeSH terms

  • Acetabulum / diagnostic imaging
  • Acetabulum / surgery*
  • Adult
  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Hip* / instrumentation
  • Bone Cements*
  • Coated Materials, Biocompatible*
  • Female
  • Femur / diagnostic imaging
  • Femur / surgery*
  • Hip Joint / diagnostic imaging
  • Hip Joint / surgery
  • Hip Prosthesis
  • Humans
  • Male
  • Middle Aged
  • Osteolysis / diagnostic imaging
  • Osteolysis / surgery*
  • Prosthesis Failure*
  • Radiography
  • Reoperation
  • Retrospective Studies
  • Treatment Outcome

Substances

  • Bone Cements
  • Coated Materials, Biocompatible