Myositis associated with a Baerveldt glaucoma implant

Am J Ophthalmol. 1999 Sep;128(3):375-6. doi: 10.1016/s0002-9394(99)00131-2.

Abstract

Purpose: To describe a case of myositis in the presence of a Baerveldt glaucoma implant.

Method: Case report.

Results: A 41-year-old black woman developed myositis after placement of a Baerveldt glaucoma implant. Echography demonstrated migration of the seton plate against the medial rectus muscle insertion. Myositis resolved after removal of the Baerveldt glaucoma implant.

Conclusion: The Baerveldt glaucoma implant may have precipitated myositis in this patient.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Female
  • Foreign-Body Migration / diagnostic imaging
  • Foreign-Body Migration / etiology*
  • Glaucoma Drainage Implants / adverse effects*
  • Glaucoma, Open-Angle / surgery
  • Humans
  • Myositis / diagnostic imaging
  • Myositis / etiology*
  • Oculomotor Muscles / diagnostic imaging
  • Oculomotor Muscles / pathology*
  • Reoperation
  • Ultrasonography