Validation and use of the CALUX-bioassay for the determination of dioxins and PCBs in bovine milk

Food Addit Contam. 1998 Nov-Dec;15(8):863-75. doi: 10.1080/02652039809374723.

Abstract

There is a strong need for the development of relatively cheap and rapid bioassays for the determination of dioxins and related compounds in food. A newly developed CALUX (Chemical-Activated LUciferase gene eXpression) bioassay was tested for its possible use to determine low levels of dioxins in bovine milk. Data show that this mammalian cell-based test is very sensitive for 2,3,7,8-substituted dioxins and related PCBs, thereby reflecting the relative potencies of these compounds in comparison to TCDD (TEF-values). The limit of detection was about 50 fg of TCDD. Furthermore, the response obtained with a mixture of dioxins was additive, in accordance with the TEF-principle. Milk fat was isolated by centrifugation followed by clean-up of the fat with n-pentane, removal of the fat on a 33% H2SO4 silica column, and determination of Ah receptor agonist activity with the CALUX-bioassay. An equivalent of 67 mg fat was tested per experimental unit, resulting in a limit of quantification around 1 pg i-TEQ/g fat. To investigate the performance of the method, butter fat was cleaned and spiked with a mixture of 17 different 2,3,7,8-substituted PCDD and PCDF congeners at 1, 3, 6, 9, 12 and 15 pg TEQ/g fat, as confirmed by GC/MS. In this concentration range, the method showed a recovery of TEQs around 67% (58-87%). The reproducibility, determined in three independent series showed a CV varying between 4% and 54%, with the exception of the sample spiked at 1 pg i-TEQ (CV 97%). The repeatability determined with the sample spiked at 6 pg i-TEQ/g showed a CV of 10%. Testing of 22 bovine milk samples, taken at different sites in The Netherlands, in the CALUX-assay showed combined dioxin and dioxin-like PCB levels equivalent to 1.6 pg TCDD/g fat (range 0.2-4.6). GC/MS analysis of these samples revealed an average level of 1.7 pg i-TEQ/g fat, varying between 0.5 and 4.7 pg i-TEQ/g fat. All five samples showing a GC/MS determined dioxin content of more than 2 pg i-TEQ/g fat gave a response in the CALUX-assay corresponding to more than 2 pg TCDD/g fat. These data clearly show that the CALUX-bioassay is a promising method for the rapid and low cost screening of dioxins in bovine milk.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Biological Assay / methods*
  • Cattle
  • Dioxins / analysis*
  • Dose-Response Relationship, Drug
  • Gas Chromatography-Mass Spectrometry
  • Luciferases / drug effects
  • Luciferases / genetics
  • Luciferases / metabolism
  • Milk / chemistry*
  • Polychlorinated Biphenyls / analysis*
  • Polychlorinated Dibenzodioxins / pharmacology
  • Rats
  • Reproducibility of Results
  • Tumor Cells, Cultured

Substances

  • Dioxins
  • Polychlorinated Dibenzodioxins
  • Polychlorinated Biphenyls
  • Luciferases