Residual Impact Performance of ECC Subjected to Sub-High Temperatures.
Al-Ameri RA, Abid SR, Murali G, Ali SH, Özakça M, Vatin NI.
Al-Ameri RA, et al.
Materials (Basel). 2022 Jan 7;15(2):454. doi: 10.3390/ma15020454.
Materials (Basel). 2022.
PMID: 35057172
Free PMC article.
The test results showed that heating to 100 and 200 C did not affect the impact resistance noticeably, where the retained cracking and failure impact numbers and ductility were higher or slightly lower than those of unheated specimens. On the other hand, exposure to 300 C …
The test results showed that heating to 100 and 200 C did not affect the impact resistance noticeably, where the retained cracking and failu …