Page 1
A k-space-based method to measure and correct for temporal B0 field variations in MR temperature imaging.
Magn Reson Med. 2022 Sep;88(3):1098-1111. doi: 10.1002/mrm.29275. Epub 2022 May 16.
Magn Reson Med. 2022.
PMID: 35576148
Free PMC article.
Effects of T2 * on accuracy and precision of dynamic T1 measurements using the single reference variable flip angle method: a simulation study.
Malmberg MA, Odéen H, Parker DL.
Malmberg MA, et al.
Med Phys. 2022 Apr;49(4):2396-2412. doi: 10.1002/mp.15476. Epub 2022 Feb 15.
Med Phys. 2022.
PMID: 35066898
Free PMC article.
Item in Clipboard
A T1-based correction method for proton resonance frequency shift thermometry in breast tissue.
McLean M, Parker DL, Odéen H, Payne A.
McLean M, et al.
Med Phys. 2021 Sep;48(9):4719-4729. doi: 10.1002/mp.15085. Epub 2021 Aug 6.
Med Phys. 2021.
PMID: 34265109
Free PMC article.
Item in Clipboard
Simultaneous proton resonance frequency T1 - MR shear wave elastography for MR-guided focused ultrasound multiparametric treatment monitoring.
Odéen H, Hofstetter LW, Payne AH, Guiraud L, Dumont E, Parker DL.
Odéen H, et al.
Magn Reson Med. 2023 Jun;89(6):2171-2185. doi: 10.1002/mrm.29587. Epub 2023 Jan 19.
Magn Reson Med. 2023.
PMID: 36656135
Free PMC article.
Item in Clipboard
The influence of bone model geometries on the determination of skull acoustic properties.
Marchant JK, Clinard SR, Odéen H, Parker DL, Christensen DA.
Marchant JK, et al.
Int J Numer Method Biomed Eng. 2023 Dec;39(12):e3779. doi: 10.1002/cnm.3779. Epub 2023 Oct 4.
Int J Numer Method Biomed Eng. 2023.
PMID: 37794748
Item in Clipboard
Validation of single reference variable flip angle (SR-VFA) dynamic T1 mapping with T2 * correction using a novel rotating phantom.
Malmberg MA, Odéen H, Hofstetter LW, Hadley JR, Parker DL.
Malmberg MA, et al.
Magn Reson Med. 2024 Apr;91(4):1419-1433. doi: 10.1002/mrm.29944. Epub 2023 Dec 19.
Magn Reson Med. 2024.
PMID: 38115639
Item in Clipboard
A Non-Contrast Multi-Parametric MRI Biomarker for Assessment of MR-Guided Focused Ultrasound Thermal Therapies.
Johnson S, Zimmerman B, Odeen H, Shea J, Winkler N, Factor R, Joshi S, Payne A.
Johnson S, et al.
IEEE Trans Biomed Eng. 2024 Jan;71(1):355-366. doi: 10.1109/TBME.2023.3303445. Epub 2023 Dec 22.
IEEE Trans Biomed Eng. 2024.
PMID: 37556341
Free PMC article.
Item in Clipboard
Cite
Cite