Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1997 1
2001 1
2003 3
2004 1
2005 1
2007 1
2010 2
2011 1
2012 4
2013 7
2014 5
2015 2
2016 1
2017 1
2018 1
2019 1
2021 3
2022 3
2023 4
2024 3

Text availability

Article attribute

Article type

Publication date

Search Results

42 results

Results by year

Filters applied: . Clear all
Page 1
Varus stress MRI in the refined assessment of the posterolateral corner of the knee joint.
Ciba M, Winkelmeyer EM, Schock J, Westfechtel S, Nolte T, Knobe M, Prescher A, Kuhl C, Truhn D, Nebelung S. Ciba M, et al. Sci Rep. 2022 Jul 13;12(1):11858. doi: 10.1038/s41598-022-15787-2. Sci Rep. 2022. PMID: 35831396 Free PMC article.
Ten human cadaveric knee joint specimens underwent imaging in each condition as above, and both unloaded and loaded using an MR-compatible device that standardized loading (of 147 N) and position (at 30 flexion). Following manual segmentation, 3D joint models were used to …
Ten human cadaveric knee joint specimens underwent imaging in each condition as above, and both unloaded and loaded using an MR-compatible d …
Fast, Accurate, and Robust T2 Mapping of Articular Cartilage by Neural Networks.
Müller-Franzes G, Nolte T, Ciba M, Schock J, Khader F, Prescher A, Wilms LM, Kuhl C, Nebelung S, Truhn D. Müller-Franzes G, et al. Diagnostics (Basel). 2022 Mar 11;12(3):688. doi: 10.3390/diagnostics12030688. Diagnostics (Basel). 2022. PMID: 35328240 Free PMC article.
Following in-situ acquisition of T2 maps in seven human cadaveric knee joint specimens at high and low signal-to-noise ratios, the NN and LSE methods were used to estimate the T2 relaxation times of the manually segmented patellofemoral cartilage. In-silico modeling at low …
Following in-situ acquisition of T2 maps in seven human cadaveric knee joint specimens at high and low signal-to-noise ratios, the NN and LS …
Getting Cartilage Thickness Measurements Right: A Systematic Inter-Method Comparison Using MRI Data from the Osteoarthritis Initiative.
Nolte T, Westfechtel S, Schock J, Knobe M, Pastor T, Pfaehler E, Kuhl C, Truhn D, Nebelung S. Nolte T, et al. Cartilage. 2023 Mar;14(1):26-38. doi: 10.1177/19476035221144744. Epub 2023 Jan 19. Cartilage. 2023. PMID: 36659857 Free PMC article.
In lack of a standard method, this study systematically compared five methods for automatic cartilage thickness measurements across the knee joint and as a function of region and sub-region: 3D mesh normals (3D-MN), 3D nearest neighbors (3D-NN), 3D ray tracing (3D-RT), 2D centerl …
In lack of a standard method, this study systematically compared five methods for automatic cartilage thickness measurements across the knee …
Comparative evaluation of pelvic allograft selection methods.
Bousleiman H, Paul L, Nolte LP, Reyes M. Bousleiman H, et al. Ann Biomed Eng. 2013 May;41(5):931-8. doi: 10.1007/s10439-013-0739-0. Epub 2013 Jan 9. Ann Biomed Eng. 2013. PMID: 23299829 Free article.
This paper presents a firsthand comparative evaluation of three different existing methods for selecting a suitable allograft from a bone storage bank. The three examined methods are manual selection, automatic volume-based registration, and automatic surface-based registr …
This paper presents a firsthand comparative evaluation of three different existing methods for selecting a suitable allograft from a bone st …
Comprehensive Assessment of Medial Knee Joint Instability by Valgus Stress MRI.
Ciba M, Winkelmeyer EM, Schock J, Schad P, Kotowski N, Nolte T, Wollschläger LM, Knobe M, Prescher A, Kuhl C, Truhn D, Nebelung S. Ciba M, et al. Diagnostics (Basel). 2021 Aug 9;11(8):1433. doi: 10.3390/diagnostics11081433. Diagnostics (Basel). 2021. PMID: 34441368 Free PMC article.
Specimens were imaged in 30 of flexion in the unloaded and loaded configurations (15 kp) and in the intact, partially sMCL-deficient, completely sMCL-deficient, and sMCL- and ACL-deficient conditions using morphologic sequences and a dedicated pressure-controlled loading device. …
Specimens were imaged in 30 of flexion in the unloaded and loaded configurations (15 kp) and in the intact, partially sMCL-deficient, comple …
Datawarehouse-enabled quality control of atrial fibrillation detection in the stroke unit setting.
Andina ME, Nelde A, Nolte CH, Scheitz JF, Olma MC, Krämer M, Meisel E, Bingel A, Meisel A, Scheibe F, Endres M, Schlemm L, Meisel C. Andina ME, et al. Heliyon. 2023 Jul 19;9(8):e18432. doi: 10.1016/j.heliyon.2023.e18432. eCollection 2023 Aug. Heliyon. 2023. PMID: 37534004 Free PMC article.
Each ECG segment plot was uploaded into a REDCap database and categorized as either AF, non-AF or artifact by manual review. Atrial flutter was subsumed as AF. These classifications were then matched with 1) medical history and known diseases before stroke, 2) discharge di …
Each ECG segment plot was uploaded into a REDCap database and categorized as either AF, non-AF or artifact by manual review. Atrial f …
Microstructural analysis of pineal volume using trueFISP imaging.
Bumb JM, Brockmann MA, Groden C, Nolte I. Bumb JM, et al. World J Radiol. 2013 Apr 28;5(4):166-72. doi: 10.4329/wjr.v5.i4.166. World J Radiol. 2013. PMID: 23671752 Free PMC article.
Pineal gland volume (PGV), cystic volume, and parenchyma volume (cysts excluded) were measured manually. RESULTS: Overall, 40.3% of pineal glands were cystic. The median PGV was 54.6 mm(3) (78.33 89.0 mm(3)), the median cystic volume was 5.4 mm(3) (15.8 37.2 mm(3)), and th …
Pineal gland volume (PGV), cystic volume, and parenchyma volume (cysts excluded) were measured manually. RESULTS: Overall, 40.3% of p …
Anthropometric Scaling of Anatomical Datasets for Subject-Specific Musculoskeletal Modelling of the Shoulder.
Klemt C, Nolte D, Ding Z, Rane L, Quest RA, Finnegan ME, Walker M, Reilly P, Bull AMJ. Klemt C, et al. Ann Biomed Eng. 2019 Apr;47(4):924-936. doi: 10.1007/s10439-019-02207-2. Epub 2019 Jan 24. Ann Biomed Eng. 2019. PMID: 30680483 Free article.
The shoulder anatomy was modelled using a validated musculoskeletal model (UKNSM). Ten subject-specific models were developed through manual digitisation of model parameters from high-resolution MRI. ...
The shoulder anatomy was modelled using a validated musculoskeletal model (UKNSM). Ten subject-specific models were developed through man
Performance evaluation of machine-assisted interpretation of Gram stains from positive blood cultures.
Walter C, Weissert C, Gizewski E, Burckhardt I, Mannsperger H, Hänselmann S, Busch W, Zimmermann S, Nolte O. Walter C, et al. J Clin Microbiol. 2024 Apr 10;62(4):e0087623. doi: 10.1128/jcm.00876-23. Epub 2024 Mar 20. J Clin Microbiol. 2024. PMID: 38506525 Free PMC article.
Manual microscopy of Gram stains from positive blood cultures (PBCs) is crucial for diagnosing bloodstream infections but remains labor intensive, time consuming, and subjective. ...The results of assisted Gram stain interpretation were compared to those of manual m
Manual microscopy of Gram stains from positive blood cultures (PBCs) is crucial for diagnosing bloodstream infections but remains lab
Creating and Implementing a Protocol for the Management of Patients in Skeletal Traction: A Quality Improvement Project.
Cline JA, Nolte JA, Mendez GM, Willis JT, Bachinskas AJ, Benge CL, Dart BR. Cline JA, et al. Kans J Med. 2021 Oct 14;14:240-242. doi: 10.17161/kjm.vol14.15179. eCollection 2021. Kans J Med. 2021. PMID: 34671438 Free PMC article.
An anonymous pre-test utilizing a 5-point Likert scale was completed to assess RN knowledge and comfort regarding the following topics of traction care: pin care, manual traction, frame assembly, weight application and removal, skin evaluation, neurovascular checks, and re …
An anonymous pre-test utilizing a 5-point Likert scale was completed to assess RN knowledge and comfort regarding the following topics of tr …
42 results