Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2015 1
2019 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

3 results

Results by year

Filters applied: . Clear all
Page 1
Robotic-assisted total knee arthroplasty is not associated with increased risk of postoperative deep vein thrombosis.
Itou J, Kuwashima U, Itoh M, Okazaki K. Itou J, et al. J Exp Orthop. 2023 Jun 29;10(1):65. doi: 10.1186/s40634-023-00628-6. J Exp Orthop. 2023. PMID: 37382867 Free PMC article.
PURPOSE: Prolongation of operation time due to registration and pin insertion has been reported with robotic-assisted total knee arthroplasty (RATKA), and there has been concern about an increase in the postoperative incidence of deep vein thrombosis (DVT). ...
PURPOSE: Prolongation of operation time due to registration and pin insertion has been reported with robotic-assisted total knee arth …
Absorbable sternal pins improve sternal closure stability within a small deviation.
Koshiyama H, Yamazaki K. Koshiyama H, et al. Gen Thorac Cardiovasc Surg. 2015 Jun;63(6):331-4. doi: 10.1007/s11748-015-0533-z. Epub 2015 Feb 27. Gen Thorac Cardiovasc Surg. 2015. PMID: 25720972
In the wire group, models were closed using two stainless steel wires. In the wire and sternal pin group, a hydroxyapatite/poly-L-lactide acid (HA/PLLA) sternal pin was used for internal fixation in addition to wire fixation. A sternal pin was inserted inside …
In the wire group, models were closed using two stainless steel wires. In the wire and sternal pin group, a hydroxyapatite/poly-L-lac …
A successful surgical repair of intraoperative pneumothorax and the diffuse dissection of visceral pleura during liver transplantation surgery via trans-diaphragmatic approach.
Sakamoto K, Ogihara A, Mitsuboshi S, Maeda H, Matsumoto T, Isaka T, Murasugi M, Omori A, Kotera Y, Egawa H, Yamamoto M, Kanzaki M. Sakamoto K, et al. Surg Case Rep. 2019 Jan 14;5(1):7. doi: 10.1186/s40792-019-0568-y. Surg Case Rep. 2019. PMID: 30644000 Free PMC article.
Thoracoscopic observation revealed that (1) the visceral pleura of the bottom of the right lung widely expanded like a giant cyst due to the dissection from the lung parenchyma and (2) a large air leakage from a pin hole appeared in the dissected pleura. After the completi …
Thoracoscopic observation revealed that (1) the visceral pleura of the bottom of the right lung widely expanded like a giant cyst due to the …