Effect of Fresh vs Standard-issue Red Blood Cell Transfusions on Multiple Organ Dysfunction Syndrome in Critically Ill Pediatric Patients: A Randomized Clinical Trial

JAMA. 2019 Dec 10;322(22):2179-2190. doi: 10.1001/jama.2019.17478.

Abstract

Importance: The clinical consequences of red blood cell storage age for critically ill pediatric patients have not been examined in a large, randomized clinical trial.

Objective: To determine if the transfusion of fresh red blood cells (stored ≤7 days) reduced new or progressive multiple organ dysfunction syndrome compared with the use of standard-issue red blood cells in critically ill children.

Design, setting, and participants: The Age of Transfused Blood in Critically-Ill Children trial was an international, multicenter, blinded, randomized clinical trial, performed between February 2014 and November 2018 in 50 tertiary care centers. Pediatric patients between the ages of 3 days and 16 years were eligible if the first red blood cell transfusion was administered within 7 days of intensive care unit admission. A total of 15 568 patients were screened, and 13 308 were excluded.

Interventions: Patients were randomized to receive either fresh or standard-issue red blood cells. A total of 1538 patients were randomized with 768 patients in the fresh red blood cell group and 770 in the standard-issue group.

Main outcomes and measures: The primary outcome measure was new or progressive multiple organ dysfunction syndrome, measured for 28 days or to discharge or death.

Results: Among 1538 patients who were randomized, 1461 patients (95%) were included in the primary analysis (median age, 1.8 years; 47.3% girls), in which there were 728 patients randomized to the fresh red blood cell group and 733 to the standard-issue group. The median storage duration was 5 days (interquartile range [IQR], 4-6 days) in the fresh group vs 18 days (IQR, 12-25 days) in the standard-issue group (P < .001). There were no significant differences in new or progressive multiple organ dysfunction syndrome between fresh (147 of 728 [20.2%]) and standard-issue red blood cell groups (133 of 732 [18.2%]), with an unadjusted absolute risk difference of 2.0% (95% CI, -2.0% to 6.1%; P = .33). The prevalence of sepsis was 25.8% (160 of 619) in the fresh group and 25.3% (154 of 608) in the standard-issue group. The prevalence of acute respiratory distress syndrome was 6.6% (41 of 619) in the fresh group and 4.8% (29 of 608) in the standard-issue group. Intensive care unit mortality was 4.5% (33 of 728) in the fresh group vs 3.5 % (26 of 732) in the standard-issue group (P = .34).

Conclusions and relevance: Among critically ill pediatric patients, the use of fresh red blood cells did not reduce the incidence of new or progressive multiple organ dysfunction syndrome (including mortality) compared with standard-issue red blood cells.

Trial registration: ClinicalTrials.gov Identifier: NCT01977547.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Blood Preservation*
  • Child
  • Child, Preschool
  • Critical Illness / mortality
  • Critical Illness / therapy*
  • Disease Progression
  • Erythrocyte Transfusion* / adverse effects
  • Female
  • Hospital Mortality
  • Humans
  • Infant
  • Infant, Newborn
  • Intensive Care Units, Pediatric
  • Kaplan-Meier Estimate
  • Male
  • Multiple Organ Failure / mortality
  • Multiple Organ Failure / prevention & control*
  • Patient Acuity
  • Respiratory Distress Syndrome, Newborn / therapy
  • Sepsis / etiology

Associated data

  • ClinicalTrials.gov/NCT01977547