High accuracy acoustic relative humidity measurement in duct flow with air

Sensors (Basel). 2010;10(8):7421-33. doi: 10.3390/s100807421. Epub 2010 Aug 9.

Abstract

An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

Keywords: acoustics; humid air flow; relative humidity.

MeSH terms

  • Acoustics / instrumentation*
  • Air*
  • Calibration
  • Equipment Design
  • Gases / analysis
  • Humidity*
  • Reproducibility of Results
  • Temperature

Substances

  • Gases