Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1986 1
1987 4
1988 1
1989 2
1990 4
1991 3
1994 3
1996 4
1997 5
1998 6
1999 7
2000 5
2001 8
2002 5
2003 8
2004 10
2005 8
2006 21
2007 15
2008 32
2009 35
2010 40
2011 40
2012 47
2013 63
2014 57
2015 95
2016 94
2017 130
2018 165
2019 186
2020 233
2021 254
2022 315
2023 321
2024 166

Text availability

Article attribute

Article type

Publication date

Search Results

2,142 results

Results by year

Filters applied: . Clear all
Page 1
Surface Modification of Biomedical Ti and Ti Alloys: A Review on Current Advances.
Xu J, Zhang J, Shi Y, Tang J, Huang D, Yan M, Dargusch MS. Xu J, et al. Materials (Basel). 2022 Feb 25;15(5):1749. doi: 10.3390/ma15051749. Materials (Basel). 2022. PMID: 35268983 Free PMC article. Review.
Ti is widely used as a material for orthopedic implants. As rapid and effective osseointegration is a key factor for the successful application of implants, biologically inert Ti materials start to show inherent limitations, such as poor surface cell adhesion, bioac
Ti is widely used as a material for orthopedic implants. As rapid and effective osseointegration is a key factor for the successful a
Thermodynamic Assessment of Bio-Oriented Ti-Ta-Sn System.
Yan L, Peng Y, Li T, Yan L, He S, Xu T. Yan L, et al. Materials (Basel). 2021 Mar 23;14(6):1568. doi: 10.3390/ma14061568. Materials (Basel). 2021. PMID: 33806883 Free PMC article.
The influence of Ta and Sn contents on the transformation temperature and amount of alpha_hcp-Ti phase in beta_bcc-(Ti,Ta) phase has been investigated based on thermodynamic calculations. ...The presently developed thermodynamic description of the Ti-Ta-Sn sy …
The influence of Ta and Sn contents on the transformation temperature and amount of alpha_hcp-Ti phase in beta_bcc-(Ti,Ta) pha …
Effective Dehydration of Fructose Over Stable Ti-Doped SBA-15 Catalysts.
Zhu Y, Xu X, He J, Guo J, Song K. Zhu Y, et al. Front Chem. 2022 Jan 5;9:817417. doi: 10.3389/fchem.2021.817417. eCollection 2021. Front Chem. 2022. PMID: 35071193 Free PMC article.
Ti-SBA-15 catalysts with different Si/Ti ratios were characterized by characterization techniques such as elemental analysis, XRD, TEM, N(2) adsorption-desorption, NH(3)-TPD, and pyridine-FTIR. The acidity of Ti-SBA-15 catalysts could be tuned by altering add
Ti-SBA-15 catalysts with different Si/Ti ratios were characterized by characterization techniques such as elemental analysis,
High-Yield Ti(3) C(2) T(x) MXene-MoS(2) Integrated Circuits.
Xu X, Guo T, Hota MK, Kim H, Zheng D, Liu C, Hedhili MN, Alsaadi RS, Zhang X, Alshareef HN. Xu X, et al. Adv Mater. 2022 Dec;34(48):e2107370. doi: 10.1002/adma.202107370. Epub 2021 Dec 4. Adv Mater. 2022. PMID: 34719808
Ti(3) C(2) T(x) films are spray coated on glass substrates followed by vacuum annealing. ...Overall, this work indicates the tremendous potential for solution-processed Ti(3) C(2) T(x) MXene films in large-area 2D nanoelectronics....
Ti(3) C(2) T(x) films are spray coated on glass substrates followed by vacuum annealing. ...Overall, this work indicates the tremendo
High-Porosity Metal-Organic Framework Glasses.
Xu W, Hanikel N, Lomachenko KA, Atzori C, Lund A, Lyu H, Zhou Z, Angell CA, Yaghi OM. Xu W, et al. Angew Chem Int Ed Engl. 2023 Apr 11;62(16):e202300003. doi: 10.1002/anie.202300003. Epub 2023 Mar 6. Angew Chem Int Ed Engl. 2023. PMID: 36791229 Free PMC article.
We report a synthetic strategy to link titanium-oxo (Ti-oxo) clusters into metal-organic framework (MOF) glasses with high porosity though the carboxylate linkage. A new series of MOF glasses was synthesized by evaporation of solution containing Ti-oxo clusters T
We report a synthetic strategy to link titanium-oxo (Ti-oxo) clusters into metal-organic framework (MOF) glasses with high porosity t …
Ancillary ligand-regulated Ti(IV)-based metallocalixarene coordination cages for photocatalytic H(2) evolution.
Tian YQ, Cui YS, Zhu JH, Xu CQ, Yi XY, Li J, Liu C. Tian YQ, et al. Chem Commun (Camb). 2022 Aug 9;58(64):9034-9037. doi: 10.1039/d2cc03131k. Chem Commun (Camb). 2022. PMID: 35876039
High-valence Ti(IV)-based metallocalixarene coordination cages that are linked by oriented ancillary ligands are unknown so far. Herein, the first family of tunable calixarene-based coordination cages of Ti(IV) with a framework formula [Ti(12)(O(i)Pr)(12)(TBC …
High-valence Ti(IV)-based metallocalixarene coordination cages that are linked by oriented ancillary ligands are unknown so far. Here …
Ti-Si composite glycol salts: depolymerization and repolymerization studies of PET.
Yu Y, Shen G, Xu TJ, Wen R, Qiao YC, Cheng RC, Huo Y. Yu Y, et al. RSC Adv. 2023 Dec 13;13(51):36337-36345. doi: 10.1039/d3ra07376a. eCollection 2023 Dec 8. RSC Adv. 2023. PMID: 38093730 Free PMC article.
In this study, a Ti-Si-ethylene glycol salt (Ti/Si-EG) was synthesized and used as a catalyst for the depolymerization of PET-ethylene glycol to produce bis(hydroxyethyl)terephthalate (BHET), and the optimum conditions for the depolymerization were determined by res …
In this study, a Ti-Si-ethylene glycol salt (Ti/Si-EG) was synthesized and used as a catalyst for the depolymerization of PET- …
Nitrogen-Doped Ti(3)C(2)T(x) MXene Induced by Plasma Treatment with Enhanced Microwave Absorption Properties.
Xu W, Li S, Zhang W, Ouyang B, Yu W, Zhou Y. Xu W, et al. ACS Appl Mater Interfaces. 2021 Oct 20;13(41):49242-49253. doi: 10.1021/acsami.1c17015. Epub 2021 Oct 8. ACS Appl Mater Interfaces. 2021. PMID: 34622653
Ti(3)C(2)T(x) has microwave absorption (MA) properties due to its dielectric loss, but the absence of magnetic loss capability of pure Ti(3)C(2)T(x) causes unmatched impedance and unsatisfied MA performance. ...The minimum reflection loss (RL(min)) of -59.20 dB at 1
Ti(3)C(2)T(x) has microwave absorption (MA) properties due to its dielectric loss, but the absence of magnetic loss capability of pur
Ti-doped CeO(2) Stabilized Single-Atom Rhodium Catalyst for Selective and Stable CO(2) Hydrogenation to Ethanol.
Zheng K, Li Y, Liu B, Jiang F, Xu Y, Liu X. Zheng K, et al. Angew Chem Int Ed Engl. 2022 Nov 2;61(44):e202210991. doi: 10.1002/anie.202210991. Epub 2022 Oct 5. Angew Chem Int Ed Engl. 2022. PMID: 36083187
Herein, we report that Rh(1) /CeTiO(x) single-atom catalyst constructed by embedding monoatomic Rh onto Ti-doped CeO(2) support has shown a super high ethanol selectivity (99.1 %), record-breaking turnover frequency (493.1 h(-1) ), and outstanding stability. Synergistic ef …
Herein, we report that Rh(1) /CeTiO(x) single-atom catalyst constructed by embedding monoatomic Rh onto Ti-doped CeO(2) support has s …
3D printed Ti-5Cu alloy accelerates osteogenic differentiation of MC3T3-E1 cells by stimulating the M2 phenotype polarization of macrophages.
Zhao X, Zhou X, Sun H, Shi H, Song Y, Wang Q, Zhang G, Xu D. Zhao X, et al. Front Immunol. 2022 Oct 7;13:1001526. doi: 10.3389/fimmu.2022.1001526. eCollection 2022. Front Immunol. 2022. PMID: 36275667 Free PMC article.
In this study, we prepared Ti-5Cu alloy by three-dimensional printing technology and found that Ti-5Cu alloy presented a much smoother surface compared with Ti. In addition, the CCK-8 results indicated the Ti-5Cu alloy had no cytotoxicity to RAW264.7 c …
In this study, we prepared Ti-5Cu alloy by three-dimensional printing technology and found that Ti-5Cu alloy presented a much …
2,142 results