A simulation and modeling approach of coupled thermal and electrical behavior of PV panels using the artificial hummingbird algorithm and two-dimensional finite difference-based model

Heliyon. 2024 Mar 4;10(6):e27244. doi: 10.1016/j.heliyon.2024.e27244. eCollection 2024 Mar 30.

Abstract

Accurate estimation of photovoltaic (PV) panels' temperature is crucial for an accurate assessment for both the electrical and thermal aspects and performances. In this study we propose an advanced simulation approach linking a double-diode (DD) electrical model using the Artificial hummingbird algorithm; for parameter extraction; and a two-dimensional finite-difference-based thermal model. The electrical-sub model is firstly validated in comparison to experimental data figuring in literature using three types of PV technologies, with a relative error of about 2%. Then, the coupled model is validated using in-situ experimental setup consisting of the usage of thin-film PV technology, temperature sensors, weather station and an infrared camera. The results from both simulations and experiments exhibit strong alignment with a relative error of not higher than 2%; mainly due to the used material calibration uncertainties and external perturbations. This holistic model can be indeed further optimized, still, it has a potential to advance the development in the research area of PV systems.Future efforts could involve additional experimentation to validate the model for different seasons of the year.

Keywords: Double-diode model; Electrical-thermal; Finite difference; Parameter extraction; Photovoltaic.