Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1990 1
1999 1
2006 1
2007 1
2019 1
2021 3
2022 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

8 results

Results by year

Filters applied: . Clear all
Page 1
Comparison of Angiographic and Intravascular Ultrasound Vessel Measurements in Infra-Popliteal Endovascular Interventions: The Below-the-Knee Calibration Study.
Kuku KO, Garcia-Garcia HM, Finizio M, Melaku GD, Wilson VA, Beyene SS, Kahsay Y, Jones-McMeans JM, Rapoza RJ, Parikh SA, DeRubertis BG, Varcoe RL, Adams GL. Kuku KO, et al. Cardiovasc Revasc Med. 2022 Feb;35:35-41. doi: 10.1016/j.carrev.2021.09.004. Epub 2021 Sep 16. Cardiovasc Revasc Med. 2022. PMID: 34544659
Comparison of Quantitative Flow Ratio and Invasive Physiology Indices in a Diverse Population at a Tertiary United States Hospital.
Finizio M, Melaku GD, Kahsay Y, Beyene S, Kuku KO, Ben-Dor I, Hashim H, Waksman R, Garcia-Garcia HM. Finizio M, et al. Cardiovasc Revasc Med. 2021 Nov;32:1-4. doi: 10.1016/j.carrev.2021.06.115. Epub 2021 Jun 25. Cardiovasc Revasc Med. 2021. PMID: 34215559
The overall accuracy was 0.91 and area under the curve (AUC) was 0.92 (95% CI 0.87-0.97). The R-squared was 0.54 and the Bland-Altman plot showed a bias of 0.0016 (SD 0.063) and limits of agreement (LOA): Upper LOA 0.13 and Lower LOA -0.12. ...
The overall accuracy was 0.91 and area under the curve (AUC) was 0.92 (95% CI 0.87-0.97). The R-squared was 0.54 and the Bland-Altman …
Influence of left ventricular cavity size on clinical presentation in hypertrophic cardiomyopathy.
Manganelli F, Betocchi S, Losi MA, Briguori C, Pace L, Ciampi Q, Perrone-Filardi P, Salvatore M, Finizio F, Pezzella E, Chiariello M. Manganelli F, et al. Am J Cardiol. 1999 Feb 15;83(4):547-52. doi: 10.1016/s0002-9149(98)00911-4. Am J Cardiol. 1999. PMID: 10073859
LV end-diastolic diameter was correlated to peak filling rate (r = 0.37; p = 0.008). The most potent predictors of functional limitation were LV end-diastolic dimension (relative risk [RR] 0.63, confidence interval [CI] 0.45 to 0.88; p = 0.008), age (RR 1.09, CI 1.03 to 1. …
LV end-diastolic diameter was correlated to peak filling rate (r = 0.37; p = 0.008). The most potent predictors of functional limitat …