Application of a Control Scheme Based on Predictive and Linear Strategy for Improved Transient State and Steady-State Performance in a Single-Phase Quasi-Z-Source Inverter

Sensors (Basel). 2022 Mar 23;22(7):2458. doi: 10.3390/s22072458.

Abstract

Z and quasi-Z-source inverters (Z/qZSI) have a nonlinear impedance network on their dc side, which allows the system to behave as a buck-boost converter in their outputs. The challenges derived from the qZSI topology include (a) the control of the voltage and current on its nonlinear impedance network, (b) the dynamic coupling between the ac and dc variables, and (c) the fact that a unique set of switches are used to manage the power at dc and ac side of the system. In this work, a control scheme that combines a PWM linear control strategy and a strategy based on finite control state model predictive control (FCS-MPC) is proposed. The linear approach works during steady state, while the FCS-MPC works during transient states, either in the start-up of the converter or during sudden reference changes. This work aims to show that the performance of this control proposal retains the best characteristics of both schemes, which allows it to achieve high-quality waveforms and error-free steady state, as well as a quick dynamic response during transients. The feasibility of the proposal is validated through experimental results.

Keywords: FCS-MPC; hybrid control schemes; qZSI; single-phase inverters; single-phase quasi impedance source inverters.