Use of cone beam computed tomography to detect and remove a broken suture needle

Gen Dent. 2010 Nov-Dec;58(6):534-6.

Abstract

Suture needles can break when they are used to suture the oral mucosa, especially if they have been bent or if excessive force is applied. Several retrieval modalities have been discussed in the literature; these have focused mainly on locating the needle. Although the segment often is found and removed by the surgeon during the procedure, more extensive procedures and paraclinical diagnostics may be necessary. This article presents a case in which a lost suture needle was located using a cone beam computed tomography scan and retrieved via surgery.

Publication types

  • Case Reports

MeSH terms

  • Cone-Beam Computed Tomography* / methods
  • Equipment Failure
  • Female
  • Foreign Bodies / diagnostic imaging*
  • Foreign Bodies / surgery
  • Humans
  • Imaging, Three-Dimensional / methods
  • Maxilla / surgery
  • Molar, Third / surgery
  • Needles / adverse effects*
  • Palate / diagnostic imaging*
  • Surgical Flaps
  • Suture Techniques / instrumentation*
  • Tooth Extraction
  • Tooth, Impacted / surgery
  • Young Adult