Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2001 1
2002 1
2007 1
2009 2
2010 5
2011 5
2012 1
2015 3
2017 3
2018 8
2019 9
2020 5
2021 12
2022 12
2023 12
2024 4

Text availability

Article attribute

Article type

Publication date

Search Results

72 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for manual fio
Search for Manuel Fix instead (2 results)
Automated control of inspired oxygen (FiO(2) ) in preterm infants: Literature review.
Dani C. Dani C. Pediatr Pulmonol. 2019 Mar;54(3):358-363. doi: 10.1002/ppul.24238. Epub 2019 Jan 10. Pediatr Pulmonol. 2019. PMID: 30632296 Review.
Recently, systems allowing the automated control of inspired oxygen (FiO(2) ) for patient delivery to maintain target SpO(2) has been become commercially available. We reviewed literature and individuated sixteen studies on the effectiveness of automated control of FiO
Recently, systems allowing the automated control of inspired oxygen (FiO(2) ) for patient delivery to maintain target SpO(2) has been …
Automated closed-loop FiO(2) titration increases the percentage of time spent in optimal zones of oxygen saturation in pediatric patients-A randomized crossover clinical trial.
Soydan E, Ceylan G, Topal S, Hepduman P, Atakul G, Colak M, Sandal O, Sari F, Karaarslan U, Novotni D, Schultz MJ, Agin H. Soydan E, et al. Front Med (Lausanne). 2022 Aug 25;9:969218. doi: 10.3389/fmed.2022.969218. eCollection 2022. Front Med (Lausanne). 2022. PMID: 36091711 Free PMC article.
METHODS: This was a randomized crossover clinical trial comparing Adaptive Support Ventilation (ASV) 1.1 with use of a closed-loop FiO(2) system vs. ASV 1.1 with manual FiO(2) titrations. The primary endpoint was the percentage of time spent in optimal SpO(2) …
METHODS: This was a randomized crossover clinical trial comparing Adaptive Support Ventilation (ASV) 1.1 with use of a closed-loop FiO
Cerebral and splanchnic oxygenation during automated control of inspired oxygen (FiO(2) ) in preterm infants.
Dani C, Pratesi S, Luzzati M, Petrolini C, Montano S, Remaschi G, Coviello C. Dani C, et al. Pediatr Pulmonol. 2021 Jul;56(7):2067-2072. doi: 10.1002/ppul.25379. Epub 2021 Mar 26. Pediatr Pulmonol. 2021. PMID: 33773084 Clinical Trial.
METHODS: Twenty infants with gestational age <32 weeks (n = 20) were assigned in random sequence to 12 h of automated or manual adjustment of FiO(2) . Over this period, they were studied continuously by near-infrared spectroscopy (NIRS). RESULTS: We found that rS …
METHODS: Twenty infants with gestational age <32 weeks (n = 20) were assigned in random sequence to 12 h of automated or manual ad …
[Intraoperative Ventilation Approaches to One-lung Ventilation].
Bergmann A, Schilling T. Bergmann A, et al. Anasthesiol Intensivmed Notfallmed Schmerzther. 2021 May;56(5):329-341. doi: 10.1055/a-1189-8031. Epub 2021 May 26. Anasthesiol Intensivmed Notfallmed Schmerzther. 2021. PMID: 34038972 Review. German.
Recommendations for maintaining the oxygenation and methods of lung protection may contradict each other (e. g. high vs. low inspiratory oxygen fraction (FiO(2)), high vs. low tidal volume, etc.). Therefore, a high degree of pathophysiological understanding and manual
Recommendations for maintaining the oxygenation and methods of lung protection may contradict each other (e. g. high vs. low inspiratory oxy …
An observational study to quantify manual adjustments of the inspired oxygen fraction in extremely low birth weight infants.
van der Eijk AC, Dankelman J, Schutte S, Simonsz HJ, Smit BJ. van der Eijk AC, et al. Acta Paediatr. 2012 Mar;101(3):e97-104. doi: 10.1111/j.1651-2227.2011.02506.x. Epub 2011 Nov 22. Acta Paediatr. 2012. PMID: 22040264
A descriptive analysis, focused on manual FiO(2) adjustments, was performed. RESULTS: Twelve ELWB infants were included. ...Within these periods, SpO(2) was >94% for 30% and <88% for 16% of the time. CONCLUSIONS: Manual FiO(2) adjustments varied …
A descriptive analysis, focused on manual FiO(2) adjustments, was performed. RESULTS: Twelve ELWB infants were included. ...Wi …
Automated versus manual control of inspired oxygen to target oxygen saturation in preterm infants: a systematic review and meta-analysis.
Mitra S, Singh B, El-Naggar W, McMillan DD. Mitra S, et al. J Perinatol. 2018 Apr;38(4):351-360. doi: 10.1038/s41372-017-0037-z. Epub 2018 Jan 2. J Perinatol. 2018. PMID: 29296004
OBJECTIVES: To conduct a systematic review of clinical trials comparing automated versus manual fraction of inspired oxygen (FiO(2)) control to target oxygen saturation (SpO(2)) in preterm infants. DESIGN: The authors searched MEDLINE, Embase, CENTRAL, and CINAHL fr …
OBJECTIVES: To conduct a systematic review of clinical trials comparing automated versus manual fraction of inspired oxygen (FiO
Automated control of oxygen titration in preterm infants on non-invasive respiratory support.
Dargaville PA, Marshall AP, Ladlow OJ, Bannink C, Jayakar R, Eastwood-Sutherland C, Lim K, Ali SKM, Gale TJ. Dargaville PA, et al. Arch Dis Child Fetal Neonatal Ed. 2022 Jan;107(1):39-44. doi: 10.1136/archdischild-2020-321538. Epub 2021 May 7. Arch Dis Child Fetal Neonatal Ed. 2022. PMID: 33963005
MAIN OUTCOME MEASURES: Target range (TR) time (SpO(2) 90%-94% or 90%-100% if in air), periods of SpO(2) deviation, number of manual FiO(2) adjustments and oxygen requirement were compared between automated and manual control periods. ...The algorithm function …
MAIN OUTCOME MEASURES: Target range (TR) time (SpO(2) 90%-94% or 90%-100% if in air), periods of SpO(2) deviation, number of manual
Comparison of automated and manual control methods in minimal flow anesthesia.
Şerefoğlu R, Kocayiğit H, Palabıyık O, Tuna AT. Şerefoğlu R, et al. J Clin Monit Comput. 2024 Apr 25. doi: 10.1007/s10877-024-01163-0. Online ahead of print. J Clin Monit Comput. 2024. PMID: 38662297
This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mindray A9 (Shenzhen, China) anesthesia machine versus manual control by an anesthesiologist. METHODS: We randomly divided 76 patients …
This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mi …
Routine use of automated FiO(2) control in Poland: prospective registry and survey.
Wilinska M, Bachman TE, Piwowarczyk P, Kostuch M, Tousty J, Berła K, Hajdar R, Skrzypek M. Wilinska M, et al. Front Pediatr. 2023 Aug 31;11:1213310. doi: 10.3389/fped.2023.1213310. eCollection 2023. Front Pediatr. 2023. PMID: 37719452 Free PMC article.
A quarter of those infants were managed with a lower target range and three-quarters with alarms looser than European guidelines for manual SpO(2) control. The perceived primary advantages of A-FiO2 were as follows: keeping the readings in the target range, reducing exposu …
A quarter of those infants were managed with a lower target range and three-quarters with alarms looser than European guidelines for manu
Effects of closed-loop automatic control of the inspiratory fraction of oxygen (FiO(2)-C) on outcome of extremely preterm infants - study protocol of a randomized controlled parallel group multicenter trial for safety and efficacy.
Maiwald CA, Niemarkt HJ, Poets CF, Urschitz MS, König J, Hummler H, Bassler D, Engel C, Franz AR; FiO2-C Study Group. Maiwald CA, et al. BMC Pediatr. 2019 Oct 21;19(1):363. doi: 10.1186/s12887-019-1735-9. BMC Pediatr. 2019. PMID: 31630690 Free PMC article.
METHODS: An outcome-assessor-blinded, randomized controlled, parallel-group trial was designed and powered to study the effect of FiO(2)-C (in addition to routine manual control (RMC) of FiO(2)), compared to RMC only, on death and severe complications related …
METHODS: An outcome-assessor-blinded, randomized controlled, parallel-group trial was designed and powered to study the effect of FiO
72 results