Investigation of the Impact of Load on the Magnetic Field Strength of the Crane by the Magnetic Metal Memory Technique

Materials (Basel). 2020 Dec 6;13(23):5559. doi: 10.3390/ma13235559.

Abstract

The paper deals with the problem of applicability of the metal magnetic memory (MMM) technique in the crane structural inspection and monitoring. The MMM method does not require the external magnetization of a structure that results in reduction of downtime of maintenance operations. Measurement of the intensity of the self-magnetic leakage signal can be an alternative to other non-destructive methods used for inspection of a large crane's structure and equipment. However, the complexity of the residual magnetization effect in the MMM technique is the problem with its application. Thus, the magnetic flux leakage behavior on the crane girder surface under different measurements and the crane's load conditions is analyzed based on the results obtained during experiments carried out on the overhead traveling crane.

Keywords: diagnostics; gantry crane; magnetic field non-destructive evaluation; metal magnetic memory.