Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Filters
Results by year
Table representation of search results timeline featuring number of search results per year.
Year | Number of Results |
---|---|
2007 | 1 |
2012 | 1 |
2019 | 1 |
2020 | 1 |
2024 | 0 |
Search Results
3 results
Results by year
Filters applied: . Clear all
The following term was not found in PubMed: Lepolu
Page 1
Relationship between Ethane and Ethylene Diffusion inside ZIF-11 Crystals Confined in Polymers to Form Mixed-Matrix Membranes.
J Memb Sci. 2020 Jan 1;593:117440. doi: 10.1016/j.memsci.2019.117440. Epub 2019 Sep 3.
J Memb Sci. 2020.
PMID: 32863548
Free PMC article.
It was observed that the confinement of ZIF-11 crystals in ZIF-11 / Torlon MMM can lead to a decrease in the ethane intracrystalline self-diffusivity. ...Surprisingly, the intra-ZIF diffusion selectivity for ethane and ethylene was not changed appreciably by the confinemen …
It was observed that the confinement of ZIF-11 crystals in ZIF-11 / Torlon MMM can lead to a decrease in the ethane intracrystalline …
Contact de-electrification of electrostatically charged polymers.
Soh S, Kwok SW, Liu H, Whitesides GM.
Soh S, et al.
J Am Chem Soc. 2012 Dec 12;134(49):20151-9. doi: 10.1021/ja309268n. Epub 2012 Nov 27.
J Am Chem Soc. 2012.
PMID: 23153329
., polyamide 6/6 (Nylon) and polyoxymethylene (Delrin), and negatively charged polymeric beads, e.g., polytetrafluoroethylene (Teflon) and polyamide-imide (Torlon), discharge when the like-charged beads are brought into contact. ...
., polyamide 6/6 (Nylon) and polyoxymethylene (Delrin), and negatively charged polymeric beads, e.g., polytetrafluoroethylene (Teflon) and p …
Item in Clipboard
Hydrostatic low-range pressure applications of the Paris-Edinburgh cell utilizing polymer gaskets for diffuse X-ray scattering measurements.
Chapman KW, Chupas PJ, Kurtz CA, Locke DR, Parise JB, Hriljac JA.
Chapman KW, et al.
J Appl Crystallogr. 2007 Feb 1;40(Pt 1):196-198. doi: 10.1107/S0021889806047923. Epub 2007 Jan 12.
J Appl Crystallogr. 2007.
PMID: 19461850
Free PMC article.
The use of a polymeric Torlon (polyamide-imide) gasket material in a Paris-Edinburgh pressure cell for in situ high-pressure X-ray scattering measurements is demonstrated. ...
The use of a polymeric Torlon (polyamide-imide) gasket material in a Paris-Edinburgh pressure cell for in situ high-pressure X-ray sc …
Item in Clipboard
Cite
Cite