Usefulness of an Additional Filter Created Using 3D Printing for Whole-Body X-ray Imaging with a Long-Length Detector

Sensors (Basel). 2022 Jun 6;22(11):4299. doi: 10.3390/s22114299.

Abstract

We recently developed a long-length detector that combines three detectors and successfully acquires whole-body X-ray images. Although the developed detector system can efficiently acquire whole-body images in a short time, it may show problems with diagnostic performance in some areas owing to the use of high-energy X-rays during whole-spine and long-length examinations. In particular, during examinations of relatively thin bones, such as ankles, with a long-length detector, the image quality deteriorates because of an increase in X-ray transmission. An additional filter is primarily used to address this limitation, but this approach imposes a higher load on the X-ray tube to compensate for reductions in the radiation dose and the problem of high manufacturing costs. Thus, in this study, a newly designed additional filter was fabricated using 3D printing technology to improve the applicability of the long-length detector. Whole-spine anterior-posterior (AP), lateral, and long-leg AP X-ray examinations were performed using 3D-printed additional filters composed of 14 mm thick aluminum (Al) or 14 mm thick Al + 1 mm thick copper (Cu) composite material. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiation dose for the acquired X-ray images were evaluated to demonstrate the usefulness of the filters. Under all X-ray inspection conditions, the most effective data were obtained when the composite additional filter based on a 14 mm thick Al + 1 mm thick Cu material was used. We confirmed that an SNR improvement of up to 46%, CNR improvement of 37%, and radiation dose reduction of 90% could be achieved in the X-ray images obtained using the composite additional filter in comparison to the images obtained with no filter. The results proved that the additional filter made with a 3D printer was effective in improving image quality and reducing the radiation dose for X-ray images obtained using a long-length detector.

Keywords: 3D printing technology; additional filter; evaluation of image quality and dose; long leg examination; long-length detector; whole spine examination.

MeSH terms

  • Phantoms, Imaging
  • Printing, Three-Dimensional*
  • Radiation Dosage
  • Radiography
  • Signal-To-Noise Ratio
  • X-Rays

Grants and funding

This study received no funding.