Accelerated reliability testing of Cu-Al bimetallic contact by a micropattern corrosion testing platform for wire bond device application

MethodsX. 2021 Mar 26:8:101320. doi: 10.1016/j.mex.2021.101320. eCollection 2021.

Abstract

Accelerated reliability testing of integrated circuit (IC) packages, such as wire-bonded devices, is a useful tool for predicting the lifetime corrosion behavior of real-world devices. Standard tests, such as highly accelerated stress test, involves subjecting an encapsulated device to high levels of humidity and high temperature (commonly 85-121 ⁰C and 85-100% relative humidity). A major drawback of current reliability tests is that mechanistic information of what occurs between t = 0 and device failure is not captured. A novel method of in-situ investigation of the device corrosion process was developed to capture the real time mechanistic information not obtained in standard reliability testing [1]. The simple, yet effective methodology involves:•Immersing a micropattern or device directly into contaminant-spiked aqueous solution, and observing its morphological changes under optical microscope paired with a camera.•Short (2-48 h) time required for testing (compared to 24-300 h of standard tests).•No need for humidity chambers.

Keywords: Bimetallic contact; Galvanic corrosion; Packaging reliability; Wire bonding failures.