Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2010 1
2015 1
2016 1
2020 1
2021 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

3 results

Results by year

Filters applied: . Clear all
Page 1
Investigation of a biosystem based on Arthrospira platensis for air revitalisation in spacecrafts: Performance evaluation through response surface methodology.
Soreanu G, Cretescu I, Diaconu M, Cojocaru C, Ignat M, Samoila P, Harabagiu V. Soreanu G, et al. Chemosphere. 2021 Feb;264(Pt 2):128465. doi: 10.1016/j.chemosphere.2020.128465. Epub 2020 Oct 4. Chemosphere. 2021. PMID: 33091781
The removal of gas traces (NO(2), SO(2) and acetic acid vapours) was below the detection limit (e.g. above 90% removal efficiency), while the removal of CO(2) ranged between 69% and 85%, depending on the initial CO(2) concentration and the light intensity. ...
The removal of gas traces (NO(2), SO(2) and acetic acid vapours) was below the detection limit (e.g. above 90% removal efficiency), w …
Insights into siloxane removal from biogas in biotrickling filters via process mapping-based analysis.
Soreanu G. Soreanu G. Chemosphere. 2016 Mar;146:539-46. doi: 10.1016/j.chemosphere.2015.11.121. Epub 2015 Dec 30. Chemosphere. 2016. PMID: 26745382
Si removal efficiency, %) was obtained as a function of key operating parameters (e.g biogas flowrate, D4 and D5 concentration). The contour plots and the response surfaces generated for the obtained objective function indicate a minimization trend in siloxane removal perf …
Si removal efficiency, %) was obtained as a function of key operating parameters (e.g biogas flowrate, D4 and D5 concentration). The …
Empirical modelling and dual-performance optimisation of a hydrogen sulphide removal process for biogas treatment.
Soreanu G, Falletta P, Béland M, Edmonson K, Ventresca B, Seto P. Soreanu G, et al. Bioresour Technol. 2010 Dec;101(23):9387-90. doi: 10.1016/j.biortech.2010.06.113. Epub 2010 Aug 3. Bioresour Technol. 2010. PMID: 20685113
Modelling and optimisation of the process was achieved by studying two independent variables (H(2)S concentration and biogas flowrate) and two simultaneous performance criteria (H(2)S removal efficiency (%) and H(2)S loading rate (g/(m(3) bed day)), which were inversely re …
Modelling and optimisation of the process was achieved by studying two independent variables (H(2)S concentration and biogas flowrate) and t …